TMSL 097-45018-02 Issue 3: Mar 96
Page 70
RETRIEVE CONDITIONS (Contd)
condtype (Contd):
TMTIE1 = threshold for MTIE 1 second has been ex-
ceeded
TMTIE4 = threshold for MTIE 4 seconds has been ex-
ceeded
TMTIE16 = threshold for MTIE 16 seconds has been ex-
ceeded
TMTIE64 = threshold for MTIE 64 seconds has been ex-
ceeded
TMTIE128 = threshold for MTIE 128 seconds has been ex-
ceeded
TMTIE512 = threshold for MTIE 512 seconds has been ex-
ceeded
TMTIE900 = threshold for MTIE 900 seconds has been ex-
ceeded
TOOF = threshold for OOFs has been exceeded
TTVAR1 = threshold for TVAR 1 second has been ex-
ceeded
TTVAR4 = threshold for TVAR 4 seconds has been ex-
ceeded
TTVAR16 = threshold for TVAR 16 seconds has been ex-
ceeded
TTVAR64 = threshold for TVAR 64 seconds has been ex-
ceeded
TTVAR128 = threshold for TVAR 128 seconds has been ex-
ceeded
state: IS-NR = in service, normal
IS-NR,ACT = in service: active
IS-NR,EQ = in service:, equipped
OOS-MT = out of service and in maintenance
OOS-MT,MAN = out of service: manually removed
OOS-MT,FLT = out of service: fault
OOS-MT,OOT = out of service: out of tolerance
conddescr: ALARM INDICATION
SIGNAL RECEIVED = received alarm indication
CARD FAIL = card has failed
CLOCK ACTIVE = clock is active
CLOCK FREERUNNING = clock is in the freerunning mode
CLOCK IN HOLDOVER = clock is in the holdover mode
CLOCK NOT CONVERGED = clock is not locked to the input signal
DISCIPLINING REFERENCE = timing input has switched to another
SWITCHED reference
EXPANSION MAJOR = expansion shelf has a major alarm
EXPANSION MINOR = expansion shelf has a minor alarm
FRAMER FAILURE = framing
FUSE OR POWER FAIL = fuse or power at DCD system has failed
INPUT OUT OF TOLERANCE = input signal is out of the clock unitÕs pull-in
range