Issue 3: Mar 96 TMSL 097-45018-02
Page 87
RETRIEVE THRESHOLD T1 (Contd)
COMPLETED RESPONSE
<sid> <date> <time>
M <ctag> COMPLD
[ "<aid>:<montype>,,,<thlev>"] ...
"<aid>:<montype>,,,<thlev>"
;
thlev: threshold level in decimal numerals
Examples:
The following response occurs if E1 is the input:
TELECOMSOLUTIONS 96-02-08 15:04:14
M 136 COMPLD
"MRC-1-1:BPV,,,16"
"MRC-1-2:BPV,,,16"
"MRC-1-3:BPV,,,16"
"MRC-1-4:BPV,,,16"
;
The following response occurs if analog is the input:
TELECOMSOLUTIONS 96-02-08 15:04:14
M 136 COMPLD
"MRC-1-1:BPV,,,-1"
"MRC-1-2:BPV,,,-1"
"MRC-1-3:BPV,,,-1"
"MRC-1-4:BPV,,,-1"
;
ERROR RESPONSE
<sid> <date> <time>
M <ctag> DENY
<errcde>
;