operation, engine oil of the same specification and of the same
recommendedviscositymustbeused(MIL-L-6082).
After 25 hours of operation, an oil and oil filter change is
required. Refill the sump again with straight mineral oil and use
until a total of 50 hours has accumulated or oil consumption has
stabilized. After this, an oil and filter change is to be carried out
andashlessdispersantoil(MIL-L22851)shouldbenowbeused.
(2) For oil and oil filter change time intervals, refer to Lycoming
Operator's Manual and appropriate Lycoming Service
Instruction (LubricatingOilRecommendations),latestissue.
Complete procedures for oil and filter change are described in
theSA160MaintenanceManual,Chapter12.
(b) Fuel
Approved Fuel Grades
Capacity
100LLGradeAviationFuel Color: Blue
ApprovedgradesaviationfuelonlymustbeusedfortheSA160
TotalFuel: 123 l (32.2 U.S. Gallons)
Usable Fuel: 114 l (29.1 U.S. Gallons)
Unusable Fuel: 9 l (3.1 U.S. Gallons)
Forafastandcompleterefuelingofthetanksfollowthesesteps:
(1) Move aircraft in a designated fuel loading area.
CAUTION !
SECTION 8
GROUND HANDLING, SERVICING & MAINTENANCE
8-10
Feb 25, 2005