AIRCRAFT
SA 160
AIRCRAFTA I R C R A F T
Symphony
3-8
SECTION 3
EMERGENCY PROCEDURES
(j) Electrical Fire In Flight
1. Switch ALT / BAT............................................................................OFF
2. Cabin Ventilation ...................................................................CLOSED
3. Cabin Heat.......................................................................................OFF
4. Fire Extinguisher as required............................................ACTIVATE
5. All other Switches
(except ignition switch).................................................................OFF
Afterfire is completely extinguished,ventilate cabin.
If it cannot be visually determined that the fire is completely
extinguished,land as soon as possible.
Afterascertaining that fire has been extinguishedcompletely:
6. Cabin ventilation.............................................................FULL OPEN
7. Switch ALT / BAT.............................................................................ON
8. Circuit Breakers........................................................................CHECK
If the short circuit is localized:
9. Required electrics ............................................................................ON
10. Land as soon as practical to inspect damages.
WARNING !
(k) Loss Of Oil Pressure
Land as soon as possible.
Oil Temperature.............................................................................CHECK
Prepare for Landing Without Engine Power (d).