SA 160
AIRCRAFTA I R C R A F T
Symphony
AIRCRAFT
3-9
SECTION 3
EMERGENCY PROCEDURES
(l) Power Supply System Malfunction
Ammeterandvoltmetershowsapowersupplysystemmalfunction.
1. ALT Switch .....................................................................CHECK ON
2. ALT FLD circuit breaker..........................................................CHECK
and reset as required.
3. ALT Switch ..................................................................OFF then ON
Ifpowerofalternator is not restored:
4. ALTSwitch....................................................................................OFF
5. Non-essential electrical equipment.............................................OFF
6. Land as soon as practical.
(m) Excessive Rate Of Charge
Ammeter and voltmeter shows a excessive rate of charge.
1. ALT Switch ...................................................................................OFF
2. Non-essential electrical equipment.............................................OFF
3. Land as soon as practical.
(n) Icing
Watch for signs of icing conditions, immediately leave the region in
whichtheicingoccurred. If possible, change flight altitude.
Feb 25, 2005
(o) Flap Actuator Drive Failure
Flap in Motion” light stay ¨on¨ when the flaps are fully retracted or
extended.
1. FLAPS circuit breaker .......................................................................PULL
2. Land as soon as practical.