ELECTRIC BICYCLE METER KT—LCD8S Product User Manual
- 25 -
P5 parameter setting interface
P5 is power monitoring setting, when P5 setting is 0, the power monitoring is the
"real-time voltage" mode. Namely, it is the method to determine the battery capacity
based on real-time battery voltage. When P5 equals to a specified parameter, the power
monitoring is the "smart power" mode (this parameter is determined by the battery
characteristics, ordinary 24V lithium is generally is 4-11, 36V lithium is between 5_15). P5
setting ranges from 0-40, press button (UP) or button (DOWN) for selection.
P5 parameter setting method is the same to that of P2.
After finishing P5 parameter setting, press button (SW) to save the current
values, and then P5 parameter column stops flashing. Hold button (SW) for about 2
seconds to save & exit P parameter setting environment and return to the display 1.
○ Exit P Parameter Setting
Among the five P parameter settings, when each parameter setting is completed, if
held button (SW) long for about 2 seconds, all can exit the setting environment and
return to display 1, meanwhile, the current set parameters would be saved.
Under each parameter setting interface, if there’s no button operation on the meter for
more than 1 minute, and then the meter will automatically return to display 1, and the