Tas k 4
Read the
Programming File
Given that the radio powers up, the next task is to read the radios
programming file or upload a default file.
1. Use the programming application to read the programming file.
2. If the programming file can be read, save a copy on the test PC, and
go to Task 5
.
3. If the programming file cannot be read, check whether:
the radio is connected to the correct serial port of the test PC,
the Mode switch of the test unit is set to Rx,
the programming application is set-up correctly. Refer to the
troubleshooting section of the online help.
4. If the programming file can be read now, save a copy on the test PC,
and go to Tas k 5
. If not, repair the radio as described in “Accessories
Interface Faulty” on page 147.
5. If the repair succeeded without the need for replacing the main board
go to Step 6. Otherwise continue with Step 7.
6. If the programming file can be read now, save a copy on the test PC,
and go to Ta s k 5
. If the file still cannot be read, go to step 7.
7. Set up a suitable default programming file and attempt to upload it to
the radio
8. If the upload succeeds, go to Ta sk 6
. If the upload fails, continue with
Step 9.
9. If the main board was replaced or if the repair failed, re-assemble the
radio as described in “Reassembling the Radio” on page 112.
Conclude with the tasks of “Final Tasks” on page 134.
Tas k 5
Obtain the Details
of the Software
Feature Enabler
(SFE)
Use the programming application to obtain and record the details of any
software-enabled features (Tools > Optional Features).
For more information refer to the online help of the programming
application.
Tas k 6
Read the
Calibration File
Use the calibration application to read the calibration file and save it on the
test PC. If the calibration file cannot be read, set up a suitable default
calibration file and load it to the radio