15
vss™-4
Color
Reverb
Lo Cut
Range: 20Hz to 200Hz
Determines the Lo Cut frequency.
Attenuation amount is controlled via the Lo Damp
parameter.
Lo Damp
Range: 0 to -18dB
Attenuation of the frequencies below the selected
frequency via the Lo Cut parameter.
Hi Cut
Range:20Hzto20kHz
DeterminestheHiCutfrequencyfortheDiffuseFieldpart
of the Reverb.
Hi Soften
Range:-50to+50
HiSoftenisaspecialfilterusedto“soften”thehigh
frequencies of Reverb diffuse field. This is not a simple
HiCutfilterbutacomplexsetoffiltersworkingtogether
toremovethefrequenciesthatgivesa“brittle”or“harsh”
soundingReverb.HiSoftenisscaled/linkedtotheHiCut
and Hi Decay parameters.
Lo Decay
Range:0.01to2.5
Decay multiplier in relation to the Master Decay, for the
frequencies below the Lo Xover setting.
Example:WhenaDecaymultiplierissetto1.25andthe
Master Decay is 2.0 seconds the resulting decay time will
be2.5seconds.
LoMid Decay
Decay multiplier in relation to the Master Decay, for the
frequencies above the Lo Xover and below the Mid Xover
settings.Example:WhenaDecaymultiplierissetto1.25
and the Master Decay is 2.0 seconds the resulting decay
timewillbe2.5seconds.
HiMid Decay
Decay multiplier in relation to the Master Decay, for the
frequencies above the Mid Xover and below the Hi Xover
settings.
Example: When a Decay multiplier is set to 1.25 and the
Master Decay is 2.0 seconds the resulting decay time will
be 2.5 seconds.
Hi Decay
Decay multiplier in relation to the Master Decay, for the
frequenciesabovetheHiXoversetting.Example:Whena
Decaymultiplierissetto1.25andtheMasterDecayis2.0
secondstheresultingdecaytimewillbe2.5seconds.
Lo Xover
Sets the Cross-over frequency between the Lo and LoMid
Decay.
Mid Xover
Sets the Cross-over frequency between the LoMid and
HiMid Decay.
Hi Xover
Sets the Cross-over frequency between the HiMid and Hi
Decay.
Gloss
Reverb Modulation
Thealgorithmdesignershaveadjustedthediffusefield
part of the reverb to be as smooth and natural sounding as
possible. However to integrate with the source material or
togetadifferentsound,it’ssometimesneededtoaddin
modulation to the late part of the reverb.
Modulation Type
Select between different types of modulation on the five
Reverb diffuse fields.
Modulation Rate
Range:+/-50
AdjuststheRateoftheselectedmodulation.
Modulation Depth
Range: 0 - 200%
AdjuststheDepthoftheselectedmodulation.

Other manuals for TC Electronic SYSTEM 6000 MKII

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TC Electronic SYSTEM 6000 MKII and is the answer not in the manual?

TC Electronic SYSTEM 6000 MKII Specifications

General IconGeneral
BrandTC Electronic
ModelSYSTEM 6000 MKII
CategoryComputer Hardware
LanguageEnglish

Related product manuals