27
MP00000B00 V_2.6
TAD. 3D (Dati tecnici / Technical data)
Mod. OPDE 150A 175A 220A 250A 310A 370A 460A
Modulazione / Modulation Space Vector PWM
Frequenza PWM / PWM Frequency
3÷16kHz (default = 5kHz da mod. 175A ÷ 370A / 5kHz from mod. 175A ÷ 370A)
(default = 4kHz solo per mod. 150A / 4kHz only for mod. 150A)
(default = 3kHz solo per mod. 460A / 3kHz only for mod. 460A)
Segnali di riferimento / Reference Signals
Fino a N.3 riferimenti analogici programmabili (risoluzione 12 bit)
Up to Nr.3 programmable analog references (12 bit resolution)
1 ingressi in frequenza (A / A - B / B) o FREQ. E UP/DOWN
1 frequency inputs (A / A - B / B) or FREQ. AND UP/DOWN
N.1 riferimento di velocità ±10 V
Nr. 1 speed reference ±10 V
Temperatura di lavoro (3)
Working Temperature (3)
°C 0 ÷ 40
Temperatura di stoccaggio
Storage Temperature
°C -10 ÷ +60
Altitudine (4) / Altitude (4) m 1000
Vibrazioni / Vibrations g 0,2
Umidità / Humidity % <90% - condensa non ammessa / condensation not permitted
Grado di protezione / Protection Degree IP 00
(1) La connessione C56 stabilisce il tipo di sovraccarico.
(2) Corrente nominale per uso continuativo a 5kHz PWM.
(3) Temperatura ambiente ammessa fino a 45 °C. in questo caso declassare la corrente a 88% In.
(4) Per altitudine superiore ai 1000 m SLM declassare la corrente dell’1% ogni 100 m.
(1) Connection C56 determines the type of overload.
(2) Rated current for continuous duty at 5kHz PWM.
(3) Allowable ambient temperature up to 45 °C. In this case, derate current to 88% In.
(4) At altitudes above 1000 m above sea level, derate current by 1% each 100 m.