104
4.14.2 Initiate Subsystem
INITiate[:IMMediate]
Function Initialize trigger system.
If initialized, trigger in system is active (system is ready to receive trigger
signal).
If not initialized, all trigger signals are ignored.
INITiate:CONTinuous <Bool>
Function Continuously re-initiates a trigger.
If inactive, the trigger system must be re-initiated for each trigger by the
INITiate command.
Parameters
0|1, OFF|ON
Query
INITiate:CONTinuous?
Return
<Bool> 0|1
NOTE
When power supply is in the INIT state, it is impossible to change any sequence programming
parameter. Send ABORt commands to allow parameters change.
4.14.3 Instrument Subsystem
INSTrument:COUPle <DSC>
Function Defines coupling between all Power Supplies connected in a multi drop
connection (RS485).
All All power supplies connected in daisy chain (coupled power supplies)
receive communication commands.
Parameters
NONE|ALL
NOTE
INSTrument:COUPle <DSC> command preserves power supply selection command. The unit
selected by INSTrument:[N]SELect command is the only unit which will reply to query commands.
If none of the units is selected, there will not be a response to query commands.
INSTrument:[N]SELect <NR1>
Function
Enables communication with the addressed power supply.
Parameters
0 ~ 31
Query
INSTrument:[N]SELect?
Return
From 0 up to 31