104
4.14.2 Initiate Subsystem
INITiate[:IMMediate]
Function Initialize trigger system.
If initialized, trigger in system is active (system is ready to receive trigger
signal).
If not initialized, all trigger signals are ignored.
INITiate:CONTinuous <Bool>
Function Continuously re-initiates a trigger.
If inactive, the trigger system must be re-initiated for each trigger by the
NOTE
When power supply is in the INIT state, it is impossible to change any sequence programming
parameter. Send ABORt commands to allow parameters change.
4.14.3 Instrument Subsystem
INSTrument:COUPle <DSC>
Function Defines coupling between all Power Supplies connected in a multi drop
connection (RS485).
All – All power supplies connected in daisy chain (coupled power supplies)
receive communication commands.
NOTE
INSTrument:COUPle <DSC> command preserves power supply selection command. The unit
selected by INSTrument:[N]SELect command is the only unit which will reply to query commands.
If none of the units is selected, there will not be a response to query commands.
INSTrument:[N]SELect <NR1>
Enables communication with the addressed power supply.
From 0 up to 31