86
RST
Reset setting. Refer to Table 2-6.
\
Function Repeat last command. If \<CR> is received, the power supply will repeat the last
FRST
Restore factory reset parameters. Refer to Table 2-6 & Table 2-7
NOTES
1. Factory Reset does not affect advanced parallel configuration acknowledgment (does not affect
power supply configuration (Single, Master or Slave roles does not change).
2. Execution time for this command is ~250mS.
3. FRST command sets USB communication interface.
4.10.6 Output Commands
PV <NR2>
Set digital programming output voltage value in Volts
Parameters Range is limited by the power supply model, OVP and UVP settings. Refer to
MV?
Returns a measured output voltage
PC <NR2>
Set digital programming output current value in Amperes
Range is limited by the power supply model. Refer to Table 4-5.
MC?
Returns a measured output current