5.9.10.2 Slave role non-volatile memory parameters
Refer to Table 5-4: Slave Role Non-Volatile Memory Parameters for the default non-volatile
memory parameters set when power supply changes its role to Slave.
Function
Slave Role
Power Supply Start Mode
SAFE
Power Supply Output State
OFF
Voltage Set Point [V]
0
Current Set Point [A]
1.05 * RATED
Over Voltage Protection (OVP) [V]
1.1 * RATED or 1.2 * RATED (Model Dependent)
Under Voltage Level (UVL) [V]
0
Under Voltage Protection (UVP) Mode
OFF
Under Voltage Protection (UVP) Delay [S]
01.0
Fold-Back Mode
OFF
Fold-Back Delay [S]
01.0
Constant Power Function
OFF
Constant Power Set Point [W]
RATED VOLTAGE MULTIPLYED BY RATED CURRENT
Slew Mode
OFF
Voltage Slew Up / Down [V/mS]
999.99
Current Slew Up / Down [A/mS]
SAME AS MASTER POWER SUPPLY
Internal Resistance Function
OFF
Internal Resistance Set Point [Ω]
0.001
Voltage Reference Programming Source
DIG
Current Reference Programming Source
DIG
Analog Mode Current Limit (OCL)
OFF
Analog Programming & Monitoring Range [V]
5
Programmable Pin 1
OFF
Programmable Pin 2
OFF
Front Panel Remote Mode
LOCAL
Front Panel LOCK
OFF
Output Sense (LOC / REM)
LOC
Interlock (ILC) Function
OFF
Enable (ENA) Function
OFF
Enable (ENA) Polarity
REV
Power Supply OK (PS_OK) Delay [S]
00.01
Preload
SAME AS MASTER POWER SUPPLY
Communication Interface
Not Affected (Preserves Setting)
Communication Power Supply Address
Not Affected (Preserves Setting)
Communication Baud Rate [Baud]
Not Affected (Preserves Setting)
Communication Language
Not Affected (Preserves Setting)
LAN parameters
Not Affected (Preserves Setting), except Host Name
Special Voltage Upper Limit (SVUL)
RATED