27
本語
Br Es Nl De Fr It
Uk
user manual
14 Troubleshooting
Below is a list of problems that may arise during normal use of the equipment. If
the described remedies do not solve the problem, contact the Technical Support
Service.
Problem
Cause
Remedy
Equipment doesnt
switch on
Mains power failure.
Check the power supply at the wall socket used by the
equipment by plugging in an appliance that definitely
works.
The Circuit breaker is open.
Check that the two keys next to the switch are closed, by
pressing them fully down.
Power supply cable damaged.
Contact the Technogym Technical Support Service.
Installation problems with the power supply cable.
Check the connection.
The control panel connector has been accidentally
disconnected.
Contact the Technogym Technical Support Service.
Data incorrect or
unreliable with
equipment running
Blocked key on keypad.
If the problem persists, contact the Technogym Technical
Support Service.
Equipment next to source of radio interference (e.g.
electrical domestic appliances).
Move the equipment to another place or move the
domestic appliances.
An internal connector has become accidentally
disconnected.
Contact the Technogym Technical Support Service.
Internal contact in control panel.
Contact the Technogym Technical Support Service.