EasyManua.ls Logo

Tecnoalarm TP8-64 - Led Signaling of the Atpk Key Reader

Tecnoalarm TP8-64
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Signaling User Manual - TP8-64
2-10
2.4 LED SIGNALING OF THE ATPK KEY READER
The ATPK key reader provides coloured LED for signlaing of the alarms and system status.
2.4.1 PROGRAM STATUS LED - RED, YELLOW, GREEN
The program status LED signal the status of the first 3 programs (1...3) as follows:
z LED blinking quickly = the pre-arming phase is active.
The pre-arming phase permits arming/disarming of other programs. Then, the volontary
exclusion of zones from the detection of alarms is possible.
z LED blinking slowly = the program is partset.
The zones included in the by-pass program are temporarily disabled from the detection of
alarms.
z LED on = the program is armed
z LED off = the program is in stand-by
Arming and disarming as well as the activation and deactivation of by-pass are logged in the event buffer of the control
panel.
2.4.2 PROGRAM AND GENERAL ALARM LED - YELLOW
The general alarm LED signals the alarms as follows:
z LED blinking = a program or general alarm is active
z LED on = a program or general alarm has been stopped and stored in the event buffer of the
control panel (alarm memory)
z LED off = no alarm has occurred
The alarms are logged in the event buffer of the control panel.
The alarm LED signals:
z Program alarm
One of the first 3 programs is in alarm.
z Antimasking alarm
The radio receiver has been jammed.
z Supervision alarm
One of the radio devices has not transmitted any test signal/alarm for a period superior to the supervision interval
programmed.
z False key
An unknown key has been inserted in one of the keypoint connected.
z False code
32 or more keys have been pressed on one of the consoles and keypads connected without entering a valid code.
z GSM fault
The mobile phone does not answer to the interrogations by the GSM interface TECNOCELL for a period of
approximately 10s.
z Cut telephone line
The telephone line voltage is missing for a period of approximately 1 minute.
z Low battery
The battery voltage has fallen to a value below the minimum guaranteeing correct functioning of the control panel
(<11V) or voltage of the battery of one of the radio devices connected is insufficient (<2.7V).
z Power failure (230V AC)
LED off
LED blinking quickly
LED blinking slowly
LED on
Program in stand-by
Program in pre-arming phase
Program partset
Program armed
LED éteinte
LED clignotante
LED allumée
No alarm
Alarm active
Alarm stored (alarm memory)
LED STATUS PROGRAM
(
1…3
)
1
LED GENERAL ALARM
2