Programming User Manual - TP8-64
3-8
3.7 PROGRAMMING OF THE CODES
Select the codes menu and confirm by clicking on the # key.
Options available
z Master code
z Standard user codes
Commands available
+ yw to select the option
+ # to confirm
3.7.1 MASTER CODE
The master code is usually reserved to the owner of the system. It is always enabled
and for all programs.
Submenus
z Code
z Programs
z Attributes
CODE
Commands available
+ 0...9 to enter the value of the code
+ yw to cancel an existing code
+ EXIT to confirm and quit
PROGRAMS
Permits the association of the programs (1 to 8).
The code is enable to arm/disarm the programs associated to.
Commands available
+ yw to select the program
+ # to associate the code to the program selected
+ * to cancel the code/program association
+ EXIT to confirm and quit
ATTRIBUTES
Every code can be enabled for different functions.
Submenus
z By-pass
Enables the code for the activation of the by-pass program.
z By-pass general alarms
Enables the code for arming even if a general alarm (tamper, low battery, power
failure, supervision, trouble modules) is active.
z Hold-up
Enables the code for the activation of a hold-up alarm by decreasing the code by
one unit, e.g. if the master code is 12345, the hold-up code is 12344.
If the master code ends in 0 (e.g. 12340), the hold-up code ends in 9 (e.g. 12349).
Thanks to this function, the Master can release a silent alarm under duress
simulating disarming.
z Automatic communicator block on disarming
Enables the code for the automatic interruption of the active alarm calls and those
in queue on disarming.
z Manual communicator block
Enables the code for the manual interruption of the active alarm calls and those in
queue entering the master code again and pressing EXIT after disarming.
z Remote disab. (disabling of remote arming/disarming by phone)
Disables the code for arming/disarming of the programs (programmed
appropriately) by phone.
z Direct disab. (disabling of direct arming/disarming)
Disables the code for direct arming, i.e. simultaneous arming of all the programs
associated by entering the code followed by the #(hash) key, but is obliged to
select them manually.
z Excl. disab. (disabling of zone exclusion)
Disables both the voluntary exclusion of zones and the automatic exclusion of
open zones. If the control panel is armed in the presence of open zones, these will
release an alarm at the end of the arming phase.
Codes 4
User codes
Menu 11
Codes
Codes 3
Master code
Master code 1
Code
Master code
12345
Master code 3
Programs
Master code 4
Attributs