TP8-64 - User Manual Programming
3-7
3.6.3 CHANNELS (A...H)
The control panel provides 8 independent telephone channels (A...H) for the
transmission of alarm messages via telephone line. To every channel, one principal
telephone number and one spare telephone number are to be associated. The principal
telephone number is always called first, the spare number is called if there is no answer
to the principal number or the line is busy.
The channel executes max. 4 attempts with either number alternating the principal with
the spare number.
+ yw to select the channel
+ # to confirm
Submenus
z Principal number
z Spare number
Selection of the number
+ yw to select the number
+ # to confirm
Enter the telephone number selected (max. 15 digits).
Commands available
+ yw to cancel an existing number
+ 0...9 to enter the value requested
+ #* to add DTMF symbols to the number
+ MEM to add pauses to the number
+ EXIT to confirm and quit
3.6.4 CALL BACK
The call back function solicits the control panel to call back the installer or monitoring
station establishing itself the connection for programming or event buffer download.
This is to protect the system against attempts at sabotage inhibiting unauthorized
access to control panel programming.
Commands available
+ # to enable call back
+ * to disable call back
+ EXIT to confirm and quit
3.6.5 MOBILE PHONE
Submenus
z Answering mode
z Emergency number
ANSWERING MODE
TECNOCELL can be enabled so as to answer to incoming calls.
If enabled, the GSM interfac answers after approx. 3 rings to incoming calls transmitting
one of two prerecorded vocal messages signaling system status (control panel in stand-
by or in alarm). Teh message is repeated until shut down of the communication.
Commands available
+ # to enable the answering mode
+ * to disable the answering mode
+ EXIT to confirm and quit
Viewing of the current settings
[ ] answering mode disabled
[ # ] answering mode enabled
EMERGENCY NUMBER
TECNOCELL constantly checks the connection with the control panel. If or some
reason, the communication between the two devices is interrupted for more than 30s,
TECNOCELL executes an emergency call dialing the emergency number programmed.
Enter the emergency number (max. 15 digits).
Commands available
+ yw to cancel an existing number
+ 0...9 to enter the value requested
+ #* to add DTMF symbols to the number
+ MEM to add pauses to the number
+ EXIT to confirm and quit
Channel A 1
1st number
1st number
01155566667777
Call back
Call
Call
* NO # YES
Mobile 2
Answer [ ]
Emergency no.
01155667788
Mobile 4
Emergency no.
Mobile 2
Answer