TP8-64 - User Manual Programming
3-11
3.8.3 ATTRIBUTES
Every key can be enabled for different functions.
Submenus
z By-pass
Enables the key for the activation of the by-pass program.
z Confirmation of disarming
Enables the key for the release of a silent alarm under duress. ON insertion of the
key, a timer is activated for the delay programmed on expiry of which, if no valid
code has been entered to confirm disarming, the hold-up alarm is released.
z Automatic communicator block on disarming
Enables the code for the automatic interruption of the active alarm calls and those
in queue on disarming.
z Byp gen. al. (by-pass general alarms)
Enables the key so as to by-pass general alarms in order to arm the system in the
presence of one of the following alarm conditions: tamper, low battery, power failure,
supervision, trouble module.
z Excl. disab. (disabling of zone exclusion)
Disables both the voluntary exclusion of zones and the automatic exclusion of
open zones. If the control panel is armed in the presence of open zones, these
will release an alarm at the end of the arming phase.
z Quick disab. (disabling of quick arming)
Disables global disarming on isertion of the key. In this case, the key will
arm/disarm only the first program associated to it.
3.8.4 LEARNING
Each electronic key before use must be associated to the control panel. This process
consisting in the storage of the device ID code is commonly called learning. Every time
a key is inserted into a keypoint connected to the control panel, its code is compared
with those stored in the memory and the control panel allows the functions the key is
enabled for.
Viewing of the current settings
[ ] key not learnt (position free)
[ # ] key learnt (position occupied)
Deletion of an existing key
To delete an existing association, press the star key (*No).
Learning
On the display of the console is viewed Learn. Waiting and contemporaneously, on the
key readers TP SK6N the green key LED is blinking.
Insert the key into the key reader.
As soon as the key has been programmed, on the display of the console is viewed
Learn. Completed and contemporaneously, on the key readers TP SK6N the green
key LED becomes lit.
Remove the key from the keypoint.
Repeat the procedure for all the keys to be programmed.
3.9 PROGRAMMING OF THE WIRELESS KEYS
Select the wireless keys menu and confirm by clicking on the # key.
Commands available
+ yw to select the wireless key (from 1 to 32)
+ # to confirm the selection
Options available
z Periods
z Ass. buttons
z Attributes
z Learning
3.9.1 PERIODS
Defines the access period (from 1 to 8) during which the wireless key is enabled.
Key 01 1
Learning [ ]
Learn.
Waiting
Learn.
Completed
Menu 13
WL keys
WL keys 1
Periods
WL keys 2
Ass. buttons
WL keys 3
Attributes
WL keys 4
Learning

Related product manuals