TP8-64 - User Manual Programming
3-9
Commands available
+
yw to select the option
+ # to enable the option
+ * to disable the option
+ EXIT to confirm and quit
Viewing of the current settings
[ ] option disabled
[ # ] option enabled
3.7.2 STANDARD USER CODES
The standard user codes have the same length as the master code and can be enabled
for arming/disarming and the activation/deactivation of by-pass of determined programs.
The recognition of this codes can be limited to determined access periods. The control
panel controls up to 62 standard user codes.
+ yw to select the code 1...62
+ # to confirm
Submenus
z Code
z Access periods
z Programs
z Attributes
CODE
Commands available
+ 0...9 to enter the value of the code
+ yw to cancel an existing code
+ EXIT to confirm and quit
ACCESS PERIODS
Select the access periods (1...8) during which the code is to be enabled. Outside these
periods of time, arming/disarming and the activation/deactivation of by-pass will be
denied.
Commands available
+ yw to select the access period 1...8
+ # to enable the code during the access period
+ * to disable the code during the access period
+ EXIT to confirm and quit
Viewing of the current settings
[ ] code disabled during the access period
[ # ] code enabled during the access period
PROGRAMS
Select the programs (1...8) the code is to be enabled for.
Commands available
+ yw to select the program
+ # to associate the program to the code
+ * to undo the association
+ EXIT to confirm and quit
Viewing of the current settings
[ ] code not enabled for the program
[ # ] code enabled for the program
ATTRIBUTES
Every code can be enabled for different functions.
Submenus
z By-pass
Enables the code for the activation of the by-pass program.
z By-pass general alarms
Enables the code for arming even if a general alarm (tamper, low battery, power
failure, supervision, trouble modules) is active.
z Hold-up
Enables the code for the activation of a hold-up alarm by decreasing the code by
one unit, e.g. if the user code is 12345, the hold-up code is 12344. If the user code
ends in 0 (e.g. 12340), the hold-up code ends in 9 (e.g. 12349).
Thanks to this function, the user can release a silent alarm under duress simulating
disarming.
User codes 1
Code 01
Code 01 1
Code
Code 01 1
11111
Code 01 2
Access periods
Access periods
Period 01 [ # ]
Code 01 3
Programs
Programs
Program 01 [ # ]
Programs 1
Progr. 01 [ # ]
Code 01 4
Attributes