Tescom ACT6000 - Automatic pre-configured Telephone DELTest sequence; Pre-configured masks for manual SELT or SELT; DELT line tests; DBPO Masks; Supplied Accessories (base kit)

Tescom ACT6000
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACT6000 User Guide January 2021 Page 13 of 52
Rate evaluation (Up & Down stream) and SNR for ADSL - ADSL2+ - VDSL2 - VDSL
Plus** masks.
Automatic pre-configured Telephone DELTest sequence * (with two ACT6000 in
Master/Slave mode) for POTS link qualification *** by Signaling and Transmissive tests
according to the M.1040 voice mask.
Pre-configured masks for manual SELT or SELT / DELT line tests sequences *
· Wide band: VOICE, MODEM 56k, ISDN, HDSL 1p and 2p, E1, T1, SHDSL, ADSL,
ADSL2+, and VDSL2-12a, VDSL2-17a, VDSL2-30a, VDSL Plus **.
For VOICE and MODEM 56K is allowed the special DELT modality EIA-464 4W E&M
to perform the Insertion-Loss and Noise level on special PCM systems with separate TX
and RX unidirectional channels.
DBPO Masks - Automatic generation of the Threshold Mask for VDSL related to the
primary line parameters included the “ESEL” measured by ADSL2+ SELT Sequence *
Notes:
* by Advanced Software ASW-1/II;
** by adoption of EBM 30 (ACT-13) optional module;
*** by adopting the ACT-11 “POTS –SUB Module installed on the ACT-12 “DMM Module”.
Supplied Accessories (base kit):
ACT6000 Base Instrument, included:
- Nylon Carrying Case with pocket for accessories;
- User Guide (English or Italian language, as requested);
- AC Power Supply and Battery Charger (Line Input: 100-220 Vac; Output: 20 Vdc);
- Banana-Banana + Crocodiles cables (2.30m total length);
- Ground Cable unipolar Banana-Crocodile cable;
Extra cost Accessories and Optional HW/SW Modules
- ASW-1/II - Advanced Software 1 (see the above description).
- ACT-11 POTS Module (Subscriber Simulator for POTS for signaling tests);
- ACT-12 DMM Module (Digital Multimeter for metallic tests);
- ACT-13 EBM30 Module (Extension Band for 35 MHz operation);
- ACT-14 USB Pen-Drive 8 GB;
- ACT-15 Probes to perform Medium & High Band PSD measurement on fed lines;
- ACT-16 Plug/Probes to perform Medium & High Band PSD measurements on fed lines.
- ACT-17-B 50 dB Balanced Attenuator, High Z input / 150 Ohm output;
- ACT-17-U 50 dB Unbalanced Attenuator High Z input / 75 Ohm output, included coaxial
cable tests BNC/BNC 75 Ohm;
- ACT-18 Real Time Resistance Meter module;
- ALT-05 Headset with 2m cable and RJ-45/4 connector;
- ALT-09 Resistive Termination Set (100, 120, 135, 150 and 600 W);
- ALT-16 Triple Banana to BNC Adapter, included coaxial cable tests BNC/BNC 75 Ohm.