Do you have a question about the Tescom ACT6000 and is the answer not in the manual?
Compliance with WEEE and RoHS directives for equipment disposal.
Lists main and additional functions like Generator & Meter, Spectrum Analyzer, TDR.
Categorizes measurements into Transmissive, Events, and TDR Fault Location.
Details saving results to internal memory or exporting via USB.
Explains battery status indication and charging process via AC adapter.
Covers case, connections, display, power supply, dimensions, environment, and compliance.
Details frequency range, accuracy, output impedances, and output levels for the signal generator.
Specifies frequency range, accuracy, input ranges, noise floor, and filters for the level meter.
Details frequency ranges, impedances, resolution, and modes for spectrum/network analysis.
Describes Cross-Talk testing methods using Generator/Meter and Network Analyzer.
Specifies frequency range, accuracy, and impedances for Return Loss measurements.
Details frequency range, accuracy, and impedances for Longitudinal Balance Loss measurements.
Covers operating limits and accuracy for Single-End Insertion Loss tests.
Describes Micro-Interruptions and Impulsive Noise tests, including threshold and monitoring time.
Lists Line Immunity by White Noise injection and TDR Fault Locator specifications.
Outlines DC/AC Voltage, Loop Resistance, Insulation, Line Length, and Capacitance measurement capabilities.
Details test voltage, range, and accuracy for DC Capacitance measurements.
Specifies measuring mode, range, resolution, and accuracy for AC Capacitance.
Describes line length estimation using capacitance measurements.
Covers measuring range, frequency range, and accuracy for impedance response.
Lists dial encoder, ring detection, and hook/break specifications for POTS simulation.
Explains automatic Single-End Tests for line pre-qualification.
Details manual transmissive measurements using pre-configured masks.
Describes End-to-End tests for line qualification using two ACT6000 units.
Covers POTS link qualification via Signaling and Transmissive tests.
Lists various pre-configured masks for line tests like VOICE, ISDN, ADSL, VDSL.
Explains automatic mask generation for VDSL based on ADSL2+ SELT.
Lists items included in the base package of the ACT6000 instrument.
Details optional modules and accessories available for purchase.
Details the functions of front panel buttons like Power, Hold, Talk, and navigation keys.
Identifies and describes the various connectors and ports on the upper panel of the instrument.
Explains the intuitive human interface and use of function keys for navigation and configuration.
Illustrates the main menu structure and how to navigate through different measurement functions.
Outlines the steps to connect the instrument and select the test type for SELT sequences.
Guides on selecting test configuration, pair mode, and service type for transmissive measurements.
Instructs on initiating the Single-End-Line-Test sequence and connection warnings.
Explains how test results are displayed, including saving and exporting options.
Describes how to view detailed metallic measurements and graphs of transmissive tests.
Shows graphical representation of Local and Remote noise estimations.
Displays Return-Loss graph with marker on the 1.1MHz frequency reference.
Shows Longitudinal Balance Loss graph with marker on the worse value.
Presents TDR echogram with marker on the estimated Line End.
Displays Insertion Loss graph with marker on the 1.1MHz frequency reference.
Shows Signal-to-Noise Ratio and DMT channel amplitude.
Guides on selecting test type, service type, and connecting the instrument for single transmissive measurements.
Details MASTER unit configuration and connection for DELT sequences.
Describes SLAVE unit configuration and connection for DELT sequences.
Shows summary of DELT test results for Central Office and Subscriber sides.
Displays noise measurement graph with G3 filter for ADSL2+.
Shows Return-Loss graph with marker on 1.1MHz frequency.
Displays Longitudinal Balance-Loss graph with marker on worse point.
Shows Crosstalk graph with marker on 1.1MHz frequency.
Displays Insertion-Loss graph with marker on 1.1MHz frequency.
Shows Signal-to-Noise Ratio and DMT channel amplitude.
Explains automatic DELT operation for EIA-464 4W E&M systems.
Details MASTER unit setup for EIA-464 4W E&M tests.
Details SLAVE unit setup for EIA-464 4W E&M tests.
Shows DELT test summary results including Noise and Insertion-Loss.
Displays spectral noise measurement with typical threshold limit.
Shows Insertion-loss measurement without threshold limits.
Guides on Slave setup for POTS link qualification, including On-Hook voltage verification.
Details Master setup for POTS link qualification, including dialling parameters and test execution.
Explains how to perform call-up and dialling using the Subscriber Simulator.
Details steps for initiating a call, including line engagement and conversation.
Covers selection of dial modes (DTMF/Pulse) and tone parameter adjustments.
Guides on connecting the line and setting up the TDR fault locator for distance measurement.
Explains changing TDR front-end modes and operating modes (Normal, Relative, Peak).
Describes how to compare real-time TDR echograms with previously saved ones.
Explains performing Micro-interruptions tests in End-to-End, Single-End, and Tracking modes.
Details setting up and performing Impulsive Noise tests, including threshold and filter selection.
Guides on measuring DC/AC voltages, including setting zero and selecting measurement modes.
Explains how to measure AC/DC capacitance and estimate line length from capacitance.
Covers setting up resistance measurements, including loop resistance and line length calculation.
Details using the ACT-18 module for real-time loop resistance measurements.
Explains how to perform RFL tests to find low insulation points without external voltage.
Describes RFL testing with extraneous DC voltage, using a resistive bridge method.
Details how to perform insulation and RFL tests on lines with different cable sections.
Explains how to measure resistive balance (R-bal) of wires.
Covers measuring the impedance response of lines or loads.
Lists measurements performable with the Generator & Meter function.
Describes the capabilities of the spectrum and network analyzer.
Details settings for TX/RX parameters, measurement modes, and band filters.
Explains settings for spectrum analysis in Base and Medium Bands, including parameters and modes.
Details settings for spectrum analysis in High Bands, including parameters and modes.
Provides guides for RMS Noise and Spectral Noise measurements.
Explains PSD measurement using the Spectrum Analyzer in high impedance.
Details Return Loss measurement using the Network Analyzer.
Describes Longitudinal Balance Attenuation measurement by Network Analyzer.
Explains NEXT measurement using the Spectrum Analyzer between two lines.
Details End-to-End Insertion Loss measurement using Generator & Meter or Spectrum Analyzer.
Mentions a PC utility for converting CSV files to PDF for test reports.
Lists threshold limits for SELT electric tests (voltage, insulation).
Lists threshold limits for SELT/DELT transmissive tests (noise, return loss, etc.).
Explains configuration for automatic line tests using Advanced Software 1/II.
Details setup and verification of DSLAM parameters for FTTCab plant.
Allows adjustment of screen brightness, contrast, and background inversion.
Reserved for TesCom's Authorized Service Laboratories.
Allows selection of the instrument's language.
Allows setting the instrument's date and time.
Guides on updating the instrument's software via USB Pen-Drive.
Enables selection of cable types for automatic pre-configuration in measurements.
Shows how to verify Insertion Loss frequency response for 1 km cable types.
Guides on activating optional software modules via USB Pen-Drive.
Allows verification and configuration of transmissive threshold limits for SELT/DELT tests.
Lists specific threshold limits for various transmissive tests in DELT and SELT modes.
Details the first step of DPBO verification, saving ESEL and ABC parameters from SELT sequence.
Describes the second step of DPBO verification, operating PSD on ADSL2+ band using ESEL/ABC parameters.
Compliance with WEEE and RoHS directives for equipment disposal.
Lists main and additional functions like Generator & Meter, Spectrum Analyzer, TDR.
Categorizes measurements into Transmissive, Events, and TDR Fault Location.
Details saving results to internal memory or exporting via USB.
Explains battery status indication and charging process via AC adapter.
Covers case, connections, display, power supply, dimensions, environment, and compliance.
Details frequency range, accuracy, output impedances, and output levels for the signal generator.
Specifies frequency range, accuracy, input ranges, noise floor, and filters for the level meter.
Details frequency ranges, impedances, resolution, and modes for spectrum/network analysis.
Describes Cross-Talk testing methods using Generator/Meter and Network Analyzer.
Specifies frequency range, accuracy, and impedances for Return Loss measurements.
Details frequency range, accuracy, and impedances for Longitudinal Balance Loss measurements.
Covers operating limits and accuracy for Single-End Insertion Loss tests.
Describes Micro-Interruptions and Impulsive Noise tests, including threshold and monitoring time.
Lists Line Immunity by White Noise injection and TDR Fault Locator specifications.
Outlines DC/AC Voltage, Loop Resistance, Insulation, Line Length, and Capacitance measurement capabilities.
Details test voltage, range, and accuracy for DC Capacitance measurements.
Specifies measuring mode, range, resolution, and accuracy for AC Capacitance.
Describes line length estimation using capacitance measurements.
Covers measuring range, frequency range, and accuracy for impedance response.
Lists dial encoder, ring detection, and hook/break specifications for POTS simulation.
Explains automatic Single-End Tests for line pre-qualification.
Details manual transmissive measurements using pre-configured masks.
Describes End-to-End tests for line qualification using two ACT6000 units.
Covers POTS link qualification via Signaling and Transmissive tests.
Lists various pre-configured masks for line tests like VOICE, ISDN, ADSL, VDSL.
Explains automatic mask generation for VDSL based on ADSL2+ SELT.
Lists items included in the base package of the ACT6000 instrument.
Details optional modules and accessories available for purchase.
Details the functions of front panel buttons like Power, Hold, Talk, and navigation keys.
Identifies and describes the various connectors and ports on the upper panel of the instrument.
Explains the intuitive human interface and use of function keys for navigation and configuration.
Illustrates the main menu structure and how to navigate through different measurement functions.
Outlines the steps to connect the instrument and select the test type for SELT sequences.
Guides on selecting test configuration, pair mode, and service type for transmissive measurements.
Instructs on initiating the Single-End-Line-Test sequence and connection warnings.
Explains how test results are displayed, including saving and exporting options.
Describes how to view detailed metallic measurements and graphs of transmissive tests.
Shows graphical representation of Local and Remote noise estimations.
Displays Return-Loss graph with marker on the 1.1MHz frequency reference.
Shows Longitudinal Balance Loss graph with marker on the worse value.
Presents TDR echogram with marker on the estimated Line End.
Displays Insertion Loss graph with marker on the 1.1MHz frequency reference.
Shows Signal-to-Noise Ratio and DMT channel amplitude.
Guides on selecting test type, service type, and connecting the instrument for single transmissive measurements.
Details MASTER unit configuration and connection for DELT sequences.
Describes SLAVE unit configuration and connection for DELT sequences.
Shows summary of DELT test results for Central Office and Subscriber sides.
Displays noise measurement graph with G3 filter for ADSL2+.
Shows Return-Loss graph with marker on 1.1MHz frequency.
Displays Longitudinal Balance-Loss graph with marker on worse point.
Shows Crosstalk graph with marker on 1.1MHz frequency.
Displays Insertion-Loss graph with marker on 1.1MHz frequency.
Shows Signal-to-Noise Ratio and DMT channel amplitude.
Explains automatic DELT operation for EIA-464 4W E&M systems.
Details MASTER unit setup for EIA-464 4W E&M tests.
Details SLAVE unit setup for EIA-464 4W E&M tests.
Shows DELT test summary results including Noise and Insertion-Loss.
Displays spectral noise measurement with typical threshold limit.
Shows Insertion-loss measurement without threshold limits.
Guides on Slave setup for POTS link qualification, including On-Hook voltage verification.
Details Master setup for POTS link qualification, including dialling parameters and test execution.
Explains how to perform call-up and dialling using the Subscriber Simulator.
Details steps for initiating a call, including line engagement and conversation.
Covers selection of dial modes (DTMF/Pulse) and tone parameter adjustments.
Guides on connecting the line and setting up the TDR fault locator for distance measurement.
Explains changing TDR front-end modes and operating modes (Normal, Relative, Peak).
Describes how to compare real-time TDR echograms with previously saved ones.
Explains performing Micro-interruptions tests in End-to-End, Single-End, and Tracking modes.
Details setting up and performing Impulsive Noise tests, including threshold and filter selection.
Guides on measuring DC/AC voltages, including setting zero and selecting measurement modes.
Explains how to measure AC/DC capacitance and estimate line length from capacitance.
Covers setting up resistance measurements, including loop resistance and line length calculation.
Details using the ACT-18 module for real-time loop resistance measurements.
Explains how to perform RFL tests to find low insulation points without external voltage.
Describes RFL testing with extraneous DC voltage, using a resistive bridge method.
Details how to perform insulation and RFL tests on lines with different cable sections.
Explains how to measure resistive balance (R-bal) of wires.
Covers measuring the impedance response of lines or loads.
Lists measurements performable with the Generator & Meter function.
Describes the capabilities of the spectrum and network analyzer.
Details settings for TX/RX parameters, measurement modes, and band filters.
Explains settings for spectrum analysis in Base and Medium Bands, including parameters and modes.
Details settings for spectrum analysis in High Bands, including parameters and modes.
Provides guides for RMS Noise and Spectral Noise measurements.
Explains PSD measurement using the Spectrum Analyzer in high impedance.
Details Return Loss measurement using the Network Analyzer.
Describes Longitudinal Balance Attenuation measurement by Network Analyzer.
Explains NEXT measurement using the Spectrum Analyzer between two lines.
Details End-to-End Insertion Loss measurement using Generator & Meter or Spectrum Analyzer.
Mentions a PC utility for converting CSV files to PDF for test reports.
Lists threshold limits for SELT electric tests (voltage, insulation).
Lists threshold limits for SELT/DELT transmissive tests (noise, return loss, etc.).
Explains configuration for automatic line tests using Advanced Software 1/II.
Details setup and verification of DSLAM parameters for FTTCab plant.
Allows adjustment of screen brightness, contrast, and background inversion.
Reserved for TesCom's Authorized Service Laboratories.
Allows selection of the instrument's language.
Allows setting the instrument's date and time.
Guides on updating the instrument's software via USB Pen-Drive.
Enables selection of cable types for automatic pre-configuration in measurements.
Shows how to verify Insertion Loss frequency response for 1 km cable types.
Guides on activating optional software modules via USB Pen-Drive.
Allows verification and configuration of transmissive threshold limits for SELT/DELT tests.
Lists specific threshold limits for various transmissive tests in DELT and SELT modes.
Details the first step of DPBO verification, saving ESEL and ABC parameters from SELT sequence.
Describes the second step of DPBO verification, operating PSD on ADSL2+ band using ESEL/ABC parameters.
| Brand | Tescom |
|---|---|
| Model | ACT6000 |
| Category | Test Equipment |
| Language | English |