EasyManuals Logo

Texas Instruments CC2500 User Manual

Texas Instruments CC2500
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
CC2500
S
WRS040
C
Page
70
of
89
0x16: MCSM2
Main Radio Control State Machine
C
onfigura
tion
Bit
Field Name
Reset
R/W
Description
7:5
Reserved
R0
Reserved
4
RX_TIME_RSSI
0
R/W
Direct RX termination based on RSSI measurement (carrier
sense).
3
RX_TIME_QUAL
0
R/W
When the RX_TIME timer expires the chip stays in RX mode if
sync word is foun
d when
RX_TIME_QUAL
=0
, or either sync
word is found or PQT is set when
RX_TIME_QUAL
=1
.
2:0
RX_TIME[2:0]
7 (111)
R/W
Timeout for sync word search in RX
for both WOR mode and
normal RX operation
. The timeout is relative to the
programmed EVENT0 timeout
.
T
he RX timeout
in
µ
s is given by EVENT0·
C(
RX_TIME, WOR_RES)
·26/X
, where C is given by the table below
and
X is the crystal oscillator frequency in MHz:
RX_TIME[2:0]
WOR_RES = 0
WOR_RES = 1
WOR_RES = 2
WOR_RES = 3
0 (000)
3.6058
18.0288
32.4519
46.8750
1
(001)
1.8029
9.0144
16.2260
23.4375
2 (010)
0.9014
4.5072
8.1130
11.7188
3 (011)
0.4507
2.2536
4.0565
5.8594
4 (100)
0.2254
1.1268
2.0282
2.9297
5 (101)
0.1127
0.5634
1.0141
1.4648
6 (110)
0.0563
0.2817
0.5071
0.7324
7 (111)
Until end of packet
As
a
n example,
EVENT0=
34666
,
WOR_RES
=0
and
RX_TIME
=6
corresponds to 1.9
5
ms RX timeout
, 1 s polling
interval and 0.195% duty cycle
.
Note that WOR_RES should be 0 or 1 when using WOR because using
WOR_RES
> 1 will give a very low duty cycle.
In applications wh
ere WOR is not used all settings of
WOR_RES
can be used
.
The duty cycle
using WOR
is approximated by:
RX_TIME[2:0]
WOR_RES = 0
WOR_RES = 1
0 (000)
12.50%
1.
95%
1 (001)
6.250%
9765
ppm
2 (010)
3.125%
4883
ppm
3 (011)
1.563%
2441
ppm
4 (100)
0.781%
NA
5 (101)
0.391%
NA
6 (110)
0.195%
NA
7 (111)
NA
Note that the RC oscillator must be enabled in order to use setting 0
-
6, because the timeout counts RC oscillator
periods.
WOR mode does not need to be enabled.
The timeout counter resolution is limited: Wi
th RX_TIME
=0
, the timeout count is given by the 13 MSBs of EVENT0,
decreasing to the 7 MSBs of EVENT0 with RX_TIME
=6
.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments CC2500 and is the answer not in the manual?

Texas Instruments CC2500 Specifications

General IconGeneral
BrandTexas Instruments
ModelCC2500
CategoryTransceiver
LanguageEnglish

Related product manuals