Installation Premier 24 Installation Manual
16 INS248
4XP Zone Expander
Expander Layout
NETWORK IN
+
-
TR
+
-
TR
NETWORK OUT
JP1
Zone
2
Zone
1
TA
Aux 12v
-
+
Zone 4Zone 3
TATATA
1
ON
2 3 4
O/P
O/P
SPK+
SPK-
2- 1-
Engineers Keypad
JP4
D
S
JP2
Network IN
Terminals
Network OUT
Terminals
Outputs 1&2
Loud Speaker Terminals
Tamper Switch
Power LED
Address Switch
Zones
1 & 2
Zones
1 & 2
Aux 12V
Engineers Keypad
Interface
Com Port
Connecting Expanders
Expanders are connected to the network terminals located at
the bottom of the control panel (see pages 13 & 14 for
details).
Addressing
4XP expanders are addressed as one or (normally) two
keypads on the network. Each 4XP has to have a unique
address, which must not conflict with any keypad or any
other 4XP on the same network.
The following table shows the expander addresses & the
keypad slots that each would occupy.
Address
DIL 1 DIL 2 DIL 3 DIL 4 Keypads
1 On off off off 1 & 2
2 off On off off 2 & 3
3 off off On off 3 & 4
4 off off off On 4 (2 Zones)
Zones
The 4XP provides 4 alarm zones, 2 for each of the 2 keypad
slots it occupies. Each zone is fully programmable (see page
35) and has to be mapped to the system (see page 51).
Outputs
2 Programmable outputs are provided 1 for each of the 2
keypad slots occupied by the expander (see page 54 for
output programming)
Expander Speaker Output
One speaker output is provided for connecting one external
16 or 2 8 loudspeakers (see page 22 for details).
The speaker volume is programmed through the keypad setup
menu (see page 51)
!
The speaker is available on keypad 1 of the two
keypad slots the 4XP occupies. (ie if the 4XP address is
3, the speaker will programmed as belonging to
keypad 3).
Expander Com Port
The Com Port can be used to connect a RadioPlus
Inteligent Receiver.
iProx Module
iProx Layout
PIP0123456
Options
1
ON
2 3 4
1
ON
2 3 4
Address
RTE
N/C N/O
Com
+
T
R
Spk
+
D0
D1
C1
L1-
C2
L2- L+
Tamper
Ext Coil
Remote LED’s
Relay 1
Ext Int Ext Int
Internal Sounder
Off
On
Door Strike
Relay
Request to
Exit Input
Remote
Prox Coil
Connections
Speaker
Volume Adj
Network
Terminals
Wiegand
Interface
Connections
Speaker
Terminals
Option & Address Switches
Connection
The iProx Module is connected to the network terminals
located at the bottom of the control panel (see pages 13 &
14 for details).
Addressing
The iProx Module is addressed as a keypad and will occupy
a keypad slot on the network. The unit must have a unique
address, which must not conflict with keypad or any other
iProx Module on the same network
The following table shows the addressing:
Address
DIL 1 DIL 2 DIL 3 DIL 4
1 On off off off
2 off On off off
3 off off On off
4 off off off On
Refer to the iProx Module manual for programming and
operating instructions.