The Programming Menu Premier 24 Installation Manual
34 INS248
5.1 Zone Setup
YES to Select:-
Zone Setup
Zone 04 Attrib 1
* * * * * * * *
Zone 04 on Panel
<Entry/Exit 1
Zone 04 on Panel
Guard <
Use keys 0 - 9 to select
a zone type or use the
SCROLL key to search
Use keys 1 - 8 to select
an attribute or use the
SCROLL key to search
OMITTABLE
>* * * * * * * *
CHIME 2
* * * * * *>* *
^
Zone 01 on Panel
Entry/Exit 1
Zone 04 on Panel
Entry/Exit 1
Yes
No
Yes
Yes
No
Yes
Yes
No
No
Yes
No
Yes
Press NO to
edit zone
attributes 1
Enter zone number
e.g. 004 = Zone 004
???
Press NO to edit
the zone type
CHIME 2
* * * * * *>2 *
Zone 04 Text:
^
Use keys 0 - 9 to program
text the same way that a
mobile phone works
e.g. 7, 444, 777 = PIR
PIR
^
7 pqrs
Press NO to
edit the
zone text
Use keys 1 - 8 to select
an attribute or use the
SCROLL key to search
Yes
No
Press NO to
edit zone
attributes 2
Zone 04 Attrib 2
* * * * * * *
DOUBLE KNOCK
>* * * * * * *
ACTIVITY
* * *>* * * *
ACTIVITY
* * *>A * * *
Press NO to
select/deselect
the option
Press NO to
select/deselect
the option
Zone 04 Wiring
Double EOL <
Use keys 0 - 8 to select
a wiring type or use the
SCROLL key to search
Zone 04 Wiring
Double EOL
No
Yes
Press NO to edit
the wiring type
Yes
Zone 04 Wiring
Normally Closed<
^
Yes
Reset
Reset
Reset
Reset
Reset