1 - Advisory Volume
Controls the volume of advisory tones (entry/exit etc) from
loudspeakers connected to the control panel. 1 = minimum;
8 = maximum. (Default = 5).
2 - Chime Volume
Controls the volume level of Chime tones from
loudspeakers connected to the control panel. 1 = minimum;
8 = maximum. (Default = 3).
3 - No. Of Re-Arms
Controls the number of times that a zone will re-arm. Once
the re-arm limit has been reached, the zone is ‘Locked Out’
and will not cause any further Intruder alarms. (Default = 3).
4 - Anti-code Resets
Limits how many Anti-code Resets can be performed by the
user. Once the limit has been reached, an Intruder alarm can
only be reset using an Engineer code. This counter is cleared
every month or whenever an Engineers code is entered.
5 - Quick Count
Sets the number of 10mS pulses that are required within 30
Seconds for a zone with the ‘Quick Response’ attribute to
activate.
6 - Modem Level
Adjusts the modem attenuation when using a Com2400.
This can help when sharing a broadband line.
Modem Level 2 1 0 7 6 5 4 3
Attenuation (dB) +4 +2 0 -2 -4 -6 -8 -10
Monitor Hardware
H73!:0!3$-$6:TU
Y-0I(-!@D:508<
Yes
Y-0I(-!@D:508<
'085:0)!d()EF()$
Yes
3
def
Y-0I(-!@D:508<
3=<:$/!"5/$)<
No
Yes
'085:0)!d()EF()$
!K!.!2!O!.!G!M
No
Press NO to edit
the options
Use keys 1 - 8 to select
an attribute or use the
SCROLL key to search
Press NO to
select/deselect
the option
KL08$!G58$!2(#-:
\K!.!2!O!.!G!M
O$--!"(/D$)
!K!.!2\O!.!G!M
O$--!"(/D$)
!K!.!2\M!.!G!M
The control panel monitors many inputs for fault conditions
i.e. the panel lid tamper, bell tamper, aux fuse etc.
Each one of these options can be disabled to overcome
problems related to the devices being monitored.
P - Phone Line Fault (Default = ON)
The telephone line is monitored for faults.
A - AC Power Failure (Default = ON)
The AC Mains is monitored for faults.
F - Aux Fuse Blown (Default = ON)
The Auxiliary Fuse/PTC is monitored for faults.
B - Bell Tamper (Default = ON)
The external sounder tamper loop is monitored for faults.
A - Aux Tamper (Default = ON)
The auxiliary tamper loop is monitored for faults.
L - Panel Lid Tamper (Default = ON)
The control panel lid tamper is monitored for faults.
B - Battery Faults (Default = OFF)
The dynamic battery test is enabled.