Premier 24 Installation Manual Programming the Control Panel
INS248 77
5.9 Engineer Utilities
View Event Log
YES to Select:-
Engineer Utils
Yes
Engineer Utils
View Event Log
Yes
Use the SCROLL key to move up and
down through the log. DOWN moves to
the previous event (backwards in time)
and UP moves forwards again. Or
use one of the otkeysavailable h
Code 01 David
12:28.04 06/03
Area
Lounge PIR
00:02.12 28/10
Part
Press PART to display any
programmed zone text etc.
Zone 05 Alarm
00:02.12 28/10
Zone 05 Alarm
*00:02.12 28/10
Menu
Press AREA to switch between
Event Log & Mandatory Log
(Mandatory indicated by *)
The control panel has two Event Logs, which are time and
date stamped. The first log is a 500 event system log
which records all events that occur on the system, i.e.
Users entering their codes to arm or disarm, alarm events,
failures to arm etc.
The second log is a 500 event Mandatory log which
records only events defined as ‘mandatory’ by EN50131.
Event Log Hotkeys
When viewing the system log there are 10 hotkeys
available. These hotkeys allow certain events to be found
easier without the need for searching.
The following hotkeys are available:
#
= Priority Alarms (PA, Fire etc.)
$
= Normal Alarms (Guard, 24hr, Entry/Exit etc.)
%
= Opens and Closings (Arm, Disarm etc.)
"
= Omits and Reinstates (Zone Omits etc.)
(
= Maintenance (System Tests, Engineer Program etc.)
)
= Tampers (Zone, Bell, Aux etc.)
*
= Test Calls (Communicator Active, successful etc.)
+
= Entry/Exit (Entry and Exit Procedures)
'
= User Codes (User codes being used)
6 = Switch between Event Log & Mandatory Log
Event Log Descriptions
Log Event Description
KSW ## Active A Keyswitch zone type has been activated (zone number ##)
RKP # MEDICAL A Medical alarm (7 & 9) has occurred from keypad number #
RKP #.# FIRE A Fire alarm (4 & 6) has occurred from keypad number #
RKP AUD PA # An Audible PA alarm (1 & 3) has occurred from keypad number #
RKP SIL PA # A Silent PA alarm (1 & 3) has occurred from keypad number #
DURESS User ## has entered a Duress Code at a keypad
ALARM Active An Intruder alarm signal has been activated
BELL Active The Bell output has been activated
REARM LOCK ## Zone ## has locked out after reaching its re-arm limit (after causing an alarm)
USER ## User ## has entered their code
EXIT The Exit mode has been started
ARMING FAILED A Exit Error-Arm Fail has occurred
ENTRY The Entry mode has been started
ARMED WITH L/F The system has been armed with a Line Fault condition present
Armed The system has been armed
Disarmed The system has been disarmed
PART Armed The system has been Part Armed
TIME Armed The system was armed automatically using one of the control timers
TIME Disarmed The system was disarmed automatically using one of the control timers
DEFERRED The automatic arming mode was deferred
ALARM ABORT An Open After Alarm-Abort has occurred
REMOTE Armed The system was armed using the Wintex UDL software
REMOTE Disarmed The system was disarmed using the Wintex UDL software
QUICK Armed Quick Arm from keypad #
RECENT Armed The system has been armed recently