Premier 24 Installation Manual Specifications
INS248 87
Output Expanders
Electrical
Operating Voltage 9 – 13.7VDC
Current Consumption
Quiescent
>35mA
Network
4-wire standard 7/0.2
alarm cable up to 250m
Star, Daisy Chain or any
combination of the two
Bank 1 Outputs
O/P 1
O/P 2
O/P 3
O/P 4
O/P 5
O/P 6
O/P 7
O/P 8
Bank 2 Outputs
O/P 1
O/P 2
O/P 3
O/P 4
O/P 5
O/P 6
O/P 7
O/P 8
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
100mA switched to 0V
Environmental
Operating Temperature
-10°C (+14°F) to
+55°C (+131°F)
Storage Temperature
-20°C (-4°F) to
+60°C (+140°F)
Maximum Humidity 95% non-condensing
EMC Environment Residential
Commercial
Light Industrial
Industrial
Physical
Dimensions
150mm x 120mm x
30mm
Packed Weight 200g Approx.
Communicators
Electrical
Operating Voltage 9 – 13.7VDC
Current Consumption
Quiescent
When Active
>25mA
>80mA
Com300 Protocol
Com2400 Protocol
ComISDN Protocol
Telephone Numbers
Dialling Formats
REN
Approval
Fast Format
Contact ID
SIA Level II
EasyCom Pager
V.21 Modem (300 baud)
Fast Format
Contact ID
SIA Level II
EasyCom Pager
SMS Messaging
V.21 Modem (300-baud)
V.22 Modem (2400-baud)
Fast Format
Contact ID
SIA Level II
EasyCom Pager
SMS Messaging
V.21 Modem (300-baud)
V.34 Modem (19200 baud)
6 (up to 24 digits each)
Pulse or DTMF
1
CTR21
Environmental
Operating Temperature
-10°C (+14°F) to
+55°C (+131°F)
Storage Temperature
-20°C (-4°F) to
+60°C (+140°F)
Maximum Humidity 95% non-condensing
EMC Environment Residential
Commercial
Light Industrial
Industrial
Physical
Dimensions
150mm x 120mm x
30mm
Packed Weight 50g Approx.