Premier 24 Installation Manual Programming the Control Panel
INS248 33
Programming Text
Text is programmed in a similar way to mobile phones.
Characters are selected by pressing the corresponding
key the appropriate number of times (to select a character
on the same key, press
&
to move the cursor along).
The table below shows the keys to use and the characters
that are assigned to them:
Key Character
',
_ 0
#,
. , ? ! 1 @ “ - & % / + = $ : ;
$,
A B C 2 a b c
%,
D E F 3 d e f
",
G H I 4 g h i
(,
J K L 5 j k l
),
M N O 6 m n o
*,
P Q R S 7 p q r s
+,
T U V 8 t u V
.,
W X Y Z 9 w x y z
&,
Move Cursor
-,
Backspace (delete)
Log Off Engineer
Whenever the Engineer Programming menu is exited by
pressing
-
twice, the display will look like this:
!.-()/!78958$$)
>0)?589!@8!35:$1
!!!!
!"#$!%&!'()!*%%+
This message will stay on the display until the Engineer logs
off.
3 To log off, proceed as follows:
Enter an Engineer code
4444
, the display
should look like this:
H73!:0!3$-$6:TU
X08$!3$:#D
Press
'
or
-
, the display should look like this:
H73!:0!3$-$6:TU
G09!0AA!7NYZN77;
Press
0
to return to normal, the display will look
something like this:
!!!!
!"#$!%&!'()!*%%+
The Engineer is now logged out of the Programming
menu.
!
The Engineer will automatically be logged out 1 hour
after the last key press.
Reset the Engineers Code (User 00)
If the Engineer code (User 00) has been lost or forgotten, it
can normally be reset back to the factory default of
#$%"
. However, this can only be done if
the NVM has not been locked (see page 44 for details).
To Reset the Engineer code (User 00):
ENSURE THAT THE LID TAMPER IS OPEN
Short out the ‘Load Default’ pins for 5 seconds (with the
control panel still powered), after 5 seconds, the
sounders/keypads will bleep to indicate that the Engineer
code has been reset.
!
NO other codes/programming will be affected, it is
just the User 00 Engineer code that will be reset.
The Engineer (User 00) code can only be reset, if the NVM
has not been locked (see page 44 for details).