Premier 24 Installation Manual Installation
INS248 27
Connecting a Computer
The Premier 24 supports local uploading and downloading
between the control panel and a PC running Wintex UDL
software. Uploading and Downloading can be used to
program and interrogate the control panel.
In order for the computer to work correctly, ensure that it is
set to the following:
• UDL Password (see page 66 for details)
!
In order to upload and download to the control
panel locally, a PC-Com lead is required.
PC-Com
Aux 12V
+Batt -
A.C.
Battery NetworkBell
F5 F2 F3 F4
Engineer
Remote
Com2
JP6
Com1
Load Defaults
Tx2Rx2
Tam pStrb0V Bell+12V
Pg 1
Aux
12V
Spk -
+
-
Aux Tamp
Connecting a Printer
The Premier 24 supports printer facilities. The printer is
connected to the Com 1 connector located on the control
panel and can be used to print the control panel event log.
In order for the printer to work correctly, ensure that it is
set to the following:
• Baud Rate = 4800
• Parity = None
• Start Bits = 1
• Stop Bits = 2
• Data Bits = 8
• DTR = Normal
• Columns = 40 or 80 (see page 44)
!
In order to connect a printer to the control panel, a
PRINT-Com lead is also required.
DATAC or RS232 printer
RS232 Data
Connect to
COM1
PC-Com