Premier 24 Installation Manual Installation
INS248 17
8XE Zone Expander
The Premier 8XE Zone Expander has:
• 8 fully programmable zones
• Aux 12V Output
Expander Layout
ux 12V
(1 Amp)
Zones 9-16 or
Tamp e rs 1-8
Connector for
plugging on JP6
control panel
Connecting Expanders
The 8XE local zone expander plugs directly on to the
terminals located on the right hand side of the control panel
(see below for details). To install the local zone expander
proceed as follows:
1. Ensure that all power is removed from the control panel
(mains and battery) before attempting to fit the expander.
2. Push the four support pillars (supplied) into the four
locating holes on the control panel PCB.
3. Align the local expander connector with the 8 way plug
(JP6) on the control panel. Push expander into place,
ensuring that all four pillars clip into the four locating
holes on the local expander.
Zone Numbering
The table below shows the zone allocation when the
expanders are installed:
Configuration Panel Zones Expander Zones
8XE = Zones 1 to 8 9 to 16
8XE= Tampers 1 to 8 Tampers 1 to 8
Expander Zones
The expander has eight programmable zones (see page 21
for wiring details). Each zone is also fully programmable
(see page 34 for programming details).