Installation Premier 24 Installation Manual
24 INS248
Panel Outputs 1 - 8 and PG1
The control panel has 8 programmable outputs, which can be
used to drive auxiliary devices such as LED’s, sounders or
relays etc. (see page 55 for programming details). The table
below shows the electrical characteristics for each output:
Terminal Max Current Operation
1 100mA Switched 0V
2 100mA Switched 0V
3 100mA Switched 0V
4 100mA Switched 0V
5 100mA Switched 0V
6 100mA Switched 0V
7 100mA Switched 0V
8 100mA Switched 0V
PG1 100mA Switched 0V
L/M N/A 0V removed = Line Fault
R/R N/A 0V applied to reset
DC+ N/A +12V Power (unfused)
DC- N/A 0V Power
Wiring Outputs
The diagram below shows some typical wiring examples:
!
For details on testing outputs, see page 79.
Wiring a Stand Alone Communicator
The panel outputs can be used to trigger a stand alone
digital communicator.
The deffualt outputs are shown in the following table, see
page 55 for details of how to program outputs.
Panel Output Function
1 Fire Alarm
2 PA Alarm
3 Intruder Alarm
4 Armed
5 Zones Locked Out
6 Fault Present
7 Confirmed Alarm
8 Abort
The diagram below shows a typical wiring example:
DC +
Control Panel
Power
1
2
3
4
5
6
7
8
12V
0V
Stand Alone
Communicator
NO
NC
C
L/M R/R
DC -
Channel Inputs
Programmed
as Positive
Removed
Line
Fault
Panel Outputs
1
2
3
4
5
6
7
8
Digi
Power
!
For details on testing the outputs, see page 79.