The Programming Menu Premier 24 Installation Manual
74 INS248
Adding New Users to the System
This section covers the alteration of existing users and the
addition of new users to the system. The Premier 24 can be
assigned up to 15 users (plus Engineer).
Default User Codes
When the control panel is first powered up and the factory
default settings are loaded (see page 28 for details), only
the Engineer code and the Master User code exist.
The default Engineer user code is
#$%"
.
,
!
The Engineer is always User 00.
If the Engineer code has been lost or forgotten, it
can normally be reset back to 1234 without having
to default the entire system (see page 33 for details).
Resetting the Engineer code is only possible if the
NVM has not been locked (see page 44 for details).
,
The default Master user code is
()*+
.
,
!
The Master User is always User 01.
,
If the Master User code has been lost or forgotten, it
can be reprogrammed by the Engineer in this menu.
Programming New Users
Each User code on the system is made up of the following
elements 1, 2 or 6, 3 and 4, these are essential for the
code/TAG to function correctly, item 5 is optional.
1. User Number
When users are assigned to the system, they need to be
identified by the control panel. Each user is identified as
Users 01, 02, 03 etc. User 01 is always the Master User.
2. User Code
This is a unique 4, 5 or 6 digit code number that is assigned
to a user. The system will allow a mixture of different length
User codes. The User code must be entered at a keypad to
operate the alarm system.
3. User Types
The User type determines which options the user can
access i.e. Setup Users, System Tests etc.
4. User Options
The User Options determines which functions are available
to the user i.e. arming, disarming, omitting etc.
5. User Name Text
Each user can be assigned up to 8 characters of name
text. The name text is displayed whenever a code is
entered and also when reading the log, making
identification of people using the alarm easier.
6. Proximity TAG
As well as or instead of operating the alarm system with a code
number, it is also possible to operate it by presenting a
Proximity TAG to the keypad (this requires a Proximity keypad).
User Types
The User type determines which functions are available to
the user i.e. arming, disarming etc. In addition, the User type
also determines which options the user can access i.e.
Setup Users etc. The following User types are available:
0: Engineer
Engineers can arm, disarm, omit zones, silence alarms
and reset alarms. In addition, Engineers can access the
Programming Menu and all User menu options. Engineers
can also change their own User codes and assign new
users to the system.
!
The default Engineer User type (User 00) can assign
any User types to the system.
Engineers can only disarm the system if it was
armed using an Engineer code. They cannot disarm
the system if it was armed with a User code.
1: Master
Master users can arm, disarm, omit zones, silence alarms
and reset alarms. In addition, Master users can access all
User menu options. Master users can also change their
own User codes and assign new users to the system. The
Master user will also activate any output programmed as
‘Door Strike’.
2: Manager
Manager users can arm, disarm, omit zones, silence
alarms and reset alarms. In addition, Manager users can
access all User menu options except Setup Users.
Manager users can also change their own User codes.
3: Standard
Standard users can arm, disarm, omit zones, silence alarms
and reset alarms. In addition, Standard users can access all
User menu options except for Setup Users, System Tests,
and Change Timers. Standard users can also change their
own User codes.
4: Shunt
Shunt users are able to omit and reinstate any zone that has
been programmed as ‘Shuntable’.
5: Duress
Duress users behave the same way as Standard users.
However, Duress users will activate any outputs programmed
as ‘Panic Alarm’ or ‘Duress’ whenever their code is entered.
6: Reset Only
Reset Only users can only disarm following an alarm and
then reset and rearm the alarm again.
7: Door Strike
Door Strike users have no access to User functions or Menu
options. However, Door Strike users will activate any outputs
programmed as ‘Door Strike’ whenever their code is entered
(see page 58 for details).