Enter a configuration
number or use the
SCROLL key to search
,08A59#)(:508!%a
NR'!5<!G06?$E
??
These options control how various system functions work.
00 - No Bell Arm Fail (Default)
If the system fails to arm, an Internal alarm will occur and
the ‘Strobe’ output will activate.
Bell on Arm Fail
If the system fails to arm, an Internal alarm will occur and
the ‘Bell’ output will activate for 10 seconds.
!
The ‘Strobe’ output will also activate for 5 seconds to
indicate that the system has armed and disarmed
successfully.
01 - Bell is an SAB (Default)
The ‘Bell’ output on the control panel applies 0V when it
activates.
Bell is an SCB
The ‘Bell' output on the control panel removes 0V when it
activates.
02 - Manual BST/GMT
The system clock will not adjust itself at the beginning and
the end of the summer (the clock will have to be adjusted
manually).
Auto BST/GMT (Default)
The system clock will adjust itself at the beginning and the
end of the summer (the clock will automatically gain 1Hr on
the last Sunday in March and lose 1Hr on the last Sunday in
October.
03 - Leave Omits
When zones have been ‘Omitted’ by a user, the zones will
remain omitted until the user reinstates them.
Remove Omits (Default)
When zones have been ‘Omitted’ by a user, the zones will
be automatically reinstated when the system is disarmed.
04 - Override Com Dly (Default)
If the system is ‘Fully’ armed and an Intruder alarm occurs,
Intruder alarm events are reported to the Alarm Receiving
Centre immediately.
Enforce Com Dly
If the system is ‘Fully’ armed and an Intruder alarm occurs,
Intruder alarm events are reported to the Alarm Receiving
Centre after any programmed ‘Coms delay’ has expired (see
page 39 for details).
05 - NVM is Unlocked (Default)
The factory default settings can be reloaded by shorting the
load default pins during power up.
NVM is Locked
The factory default settings cannot be reloaded by shorting
the load default pins during power up.
!
If the NVM is locked and the Engineer User code has
been lost or forgotten, the control panel will have to
be returned to Texecom to be unlocked.
06 - Engineer Only (Default)
Access to the Engineers Programming menus can be
obtained by just entering the Engineer User code.
User + Engineer
Access to the Engineers Programming mode can only be
obtained, if a User (with the ‘Engineer Access’ attribute) has
authorised engineer access.
07 - Omit Tampers No (Default)
A user cannot omit Tamper faults on a zone.
Omit Tampers Yes
A user can omit Tamper faults on a zone.
08 - 80 Column Print (Default)
Select this option when connecting a 80 Column printer to
the control panel.
40 Column Print (Default)
Select this option when connecting a 40 Column printer to
the control panel.
09 - Hide Act. Fault (Default)
If a zone with the ‘Activity’ attribute is not activated during
the ‘Activity Delay’ time window, the system can still be
armed. However, this fault will be indicated to the user when
they try to arm.
View Act. Fault
If a zone with the ‘Activity’ attribute is not activated during
the ‘Activity Delay’ time window, the system cannot be
armed. This situation can only be overcome by activating
the zone.