The Programming Menu Premier 24 Installation Manual
78 INS248
Log Event Description
# RESET - The system has been reset using keypad # following an Intruder alarm
Engineer Reset A reset has been performed using an Engineers code
Anti-Code Reset A reset has been performed using the Anti-code reset procedure
Remote Reset A reset has been performed using the ‘Remote Reset’ input
Key switch Reset A reset has been performed using a key switch
User Reset A reset has been performed using a User code
EXP # Reset A reset has been performed using the input on expander # (programmed as reset)
Remote PC Reset A reset has been performed by the remote download PC
FUSE # FAIL The Auxiliary 12V Fuse/PTC in device # has failed
AC POWER The control panel has registered a AC Mains failure
LOW BAT The control panel has registered a low battery condition
POWERED UP System Power Up (without doing a factory restart)
BELL FUSE The control panel Bell Fuse has failed
LINE FLT There is a problem with the telephone line
Panel Line Fault The control panel line fault input has been activated
Com??? Line Fault The Com300, 2400 or ISDN has detected a line fault
COMS FAILED The Com300 or Com2400 has failed to report to the Alarm Receiving Centre
DOWNLOAD START An Upload/Download has been initiated
DOWNLOAD END The Upload/Download has finished
LOG ALERT 80% of the Event Log has filled (since the last Upload/Download)
DATE CHANGED The control panel Time has been changed
TIME CHANGED The control panel Date has been changed
PROG. START An Engineer code has been entered
PROG. END The Engineer has logged out of the Programming menu
BOX LID The control panel lid has been removed causing a Tamper alarm
BELL # Tamper A Bell Tamper input from device # has been activated
AUX # Tamper An Auxiliary Tamper input from device # has been activated
EXP # Tamper The cover of expander # has been removed
RKP # Tamper The cover of keypad # has been removed
RKP # LOST Keypad ## has been lost from the network
EXP # LOST Expander ## has been lost from the network
FIRE ## Active Zone ## (programmed as Fire Alarm) has caused an alarm
Zone ## Tamper Zone ## has caused a Tamper alarm
Zone ## Active Zone ## has been activated
Zone ## Restore Zone ## has restored to its normal condition
Zone ## Omitted Zone ## has been omitted
Zone ## Un-Omit Zone ## has been reinstated
Zone ## Test Start Zone ## has been put on test
Zone ## Test End Zone ## has been removed from test
RKP LOCKED # Keypad # has been locked out from too many invalid key presses
CODE # Tamper Too many invalid key presses have caused a tamper alarm from keypad #
TEST FAIL ##) Zone ## has failed its Soak test
MANUAL TEST CALL A Manual test call has been initiated
AUTO TEST CALL An Automatic test call has been initiated
WALK The Walk Test mode has been initiated
TESTED ## Zone ## has been tested
DEFAULTS LOADED The factory default values have been loaded into memory
FIRST KNOCK ## Zone ## (which is programmed as double knock) has activated for the first time
CURRUPT EVENT No event has been stored in memory