26 - Armed Mask = Fault (Default)
If an Anti-masking signal is detected when the system is
armed, the control panel will generate a Fault response.
Armed Mask=Alarm
If an Anti-masking signal is detected when the system is
armed, the control panel will generate an Alarm response.
27 - RF PA = Audible (Default)
PA alarms generated from an RF FOB will cause an audible
alarm.
RF PA = Silent
PA alarms generated from an RF FOB will cause a silent
alarm.
28 - Dynamic Tests (Default)
The test call timer will be reset each time the panel makes a
successful call. A test call will only be set when the
communicator has been inactive for the duration of the test
call timer.
29 -Periodic Tests
A test call will be sent every time the test call timer expires.
eg If the timer is set to 24 hours, a test call will be made
each day regardless of whether the communicator has been
active since the last test call.