EasyManua.ls Logo

Texecom Premier 24 - Adjusting Speaker Volumes; To adjust speaker volumes, proceed as follows

Texecom Premier 24
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The Programming Menu Premier 24 Installation Manual
56 INS248
15 - Coms Failed
This output type activates when the plug-on digimodem fails
to report to the Alarm Receiving Centre (after 3 dialling
attempts), and deactivates the next time the digimodem
successfully reports to the Alarm Receiving Centre.
16 - Coms Successful
This output type activates when the plug-on digimodem
successfully reports to the Alarm Receiving Centre and
deactivates the next time the digimodem is triggered.
17 - Coms Active
This output type activates when the plug-on digimodem is
triggered and deactivates when the digimodem shuts down.
18 - UDL Lockout
This output type activates when an attempt is made to
upload/download with incorrect site details more than
three times and deactivates after 4 hours or after a valid
User code is entered.
19 - UDL Call Active
This output type activates when an upload/download is
started and deactivates when the upload/download finishes.
20 - UDL Enabled
This output type activates when ‘Enable UDL/Engineer’ is
enabled and deactivates when ‘Enable UDL/Engineer’ is
disabled.
21 - Custom Output
This output type activates when ‘PGM 5 OR 6 AND 7 AND 8’
activate and deactivates when ‘any one of the same PGM
outputs deactivate (see page 59 for details).
22 - Activity Fault
This output type activates whenever a zone with the
‘Activity’ attribute has not activated and deactivates when
the zone activates.
23 - No Battery
This output type activates for 1 minute if the engineer logs off
the control panel and there is no battery fitted.
24 - Control Timer 1
This output type operates when ‘Control Timer 1’ activates
and deactivates when ‘Control Timer 1’ deactivates.
25 - Control Timer 2
This output type operates when ‘Control Timer 2’ activates
and deactivates when ‘Control Timer 2’ deactivates.
26 - Control Timer 3
This output type operates when ‘Control Timer 3’ activates
and deactivates when ‘Control Timer 3’ deactivates.
27 - Control Timer 4
This output type operates when ‘Control Timer 4’ activates
and deactivates when ‘Control Timer 4’ deactivates.
28 - Com Port 1 Fault
This output type activates when whatever is connected to
Com Port 1 stops communicating with the control panel
and deactivates when communication starts again.
29 - Com Port 2 Fault
This output type activates when whatever is connected to
Com Port 2 stops communicating with the control panel
and deactivates when communication starts again.
30 - Code Accepted
This output type activates for 5 seconds whenever a User
code is entered.
31 - Prox TAG Accepted
This output type activates for 5 seconds whenever a
Proximity TAG is presented.
32 - Radio Jamming
This output type activates whenever the wireless radio
receiver detects a jamming signal and deactivates when
the jamming signal is removed.
33 - Detector Test
This output type is activated via Wintex to initiate a
diagnostics check on an PD6662: 2004/EN 50131-1 Grade
3 detector and deactivates after 10 seconds.
34 - ATS Remote Test
This output type conforms to the BSIA Form 175
Specification. When a Line Fault is not present it can be
activated remotely by Wintex, or by using the ‘Start Test
Call’ option on the control panel to initiate a test on ATE
equipment that have an ATS test input. NOTE: Only the
RedCare Line Fault and Control panel Line Fault inputs can
be used with the output type.
35 - No ATS Available
This output type activates when no signalling paths are
available for the Alarm Transmission System (ATS) and
deactivates when one or more paths become available.
36 - CIE Fault
This output type activates when a fault occurs on the CIE
and deactivates when the fault is cleared.
37 - PSU Fuse Blown
This output type activates when the Auxiliary input type
‘PSU Monitor’ detects a 12V failure and deactivates when
the fault is reset.
38 - PSU Battery Flt
This output type activates when the Auxiliary input type
‘PSU Monitor’ detects a battery fault and deactivates when
the fault is reset.
39 - iD Loop Shorted
This output type activates when the 24iXD detects a short
circuit on the iD loop and deactivates when the fault is
reset
40 – Radioplus Tamper
This output type activates when the intelligent receiver
detects a lid tamper.
41 – GSM No Signal
This output type activates when a GSM device losses the
network signal.