The Programming Menu Premier 24 Installation Manual
58 INS248
27 - Bell SAB
This output type activates when an Alarm occurs and
deactivates when the alarm is cancelled or the ‘Bell Duration’
timer expires.
28 - Strobe
This output type activates when an Alarm occurs and
deactivates when the alarm is cancelled or the system is
disarmed
29 - Detector Latch
This output type activates for 5 seconds when the exit
mode is started then reactivates when the system arms.
The output type deactivates when an Intruder alarm occurs
or the system is disarmed.
30 - Detector Reset
This output type is normally active and deactivates for 5
seconds when the exit mode is started.
31 - Walk Test Active
This output type activates when the ‘Walk Test’ procedure
is started, and deactivates when the ‘Walk Test’ procedure
is finished.
32 - Zones Omitted
This output type activates when a zone with the ‘Omit’
attribute, is omitted, and deactivates when the zone is
reinstated.
33 - 24Hr Zones Omit
This output type activates when a zone programmed as
‘24Hr Audible’ (with the ‘Omit’ attribute) is omitted by the
user and deactivates when the zone is reinstated.
34 - Reset Required
This output type activates when the system requires a reset
following an alarm and deactivates when the alarm is reset.
35 - Door Strike
This output type activates for the duration of the ‘Door
Strike’ timer when a User code with the ‘Door Strike’
attribute is entered.
36 - Chime Mimic
This output type activates for 2 seconds when a zone with
the ‘Chime’ attribute is activated.
37 - Chime Enabled
This output type activates when ‘Chime’ is enabled and
deactivates when ‘Chime’ is disabled.
38 - DK First Knock
This output type activates when a zone with the ‘Double
Knock’ attribute is activated for the first time and
deactivates when the zone causes an alarm or the ‘Double
Knock Delay’ timer expires.
39 - On Test
This output type activates when a zone with the ‘Test’
attribute is placed on test and deactivates when the ‘Soak
Test Time’ expires.
40 - Test Fail
This output type activates when a zone with the ‘Test’ attribute
activates and deactivates when an Engineer code is entered.
41 - Internal Alarm
This output type activates when an Internal alarm occurs and
deactivates when the alarm is cancelled.
42 - Time Arming
This output type activates for 5 minutes prior to the system
being armed using the ‘Control Timers’.
43 - Part Armed 1
This output type activates when a Part Arm 1 is selected
and deactivates when part arm 1 is not selected.
44 - Part Armed 2
This output type activates when a Part Arm 2 is selected
and deactivates when part arm 2 is not selected.
45 - Part Armed 3
This output type activates when a Part Arm 3 is selected
and deactivates when part arm 3 is not selected.
46 - Zones Locked Out
This output type activates when any zone is locked out
following an Intruder Alarm activation and deactivates
when all zones are clear and reinstated.
47 - Armed/Alarm
This output type activates when the system is armed and
deactivates when the system is disarmed
This output type also pulses when an Intruder alarm
occurs, and deactivates when the system is disarmed.
48 - Full Arm Entry
This output type activates when the entry mode is started
and deactivates when the entry mode finishes whenever
the system in Full Armed.
49 - Intruder Alarm
This output type activates when an Intruder alarm occurs,
and deactivates when the Intruder alarm is cancelled.
Tamper alarms will not activate this output
50 - Speaker Mimic
This output type activates whenever the internal speaker
output is on, and deactivates when the speaker output is off.
51 - Detector Fault
This output type activates when a detector fault occurs and
deactivates when the fault is reset.
52 - Detector Masked
This output type activates when a detector mask occurs
and deactivates when the mask is reset.
53 - Fault Present
This output type activates when a general fault occurs i.e.
Line Fault, AC Mains Fail, Detector Fault etc. and
deactivates when the fault is cleared.
54 - LED Control
This output type is always activate and deactivates when a
User or Engineers code is entered to gain access to a
menu. The output activates again 30 seconds after the
user/engineer exits the menu. This output type is for use
with detectors that require 0V applied to disable their
LED’s.