INS248 69
No Zone Type Event Reporting Group Contact ID SIA
10 Auxiliary Alarm Alarm Tamper 150 UA
Alarm Restore Restore 150 UH
Omit Omit/Reinstate 572 UB
Reinstate Omit/Reinstate 572 UU
11 24Hr Tamper Alarm Alarm Tamper 137 TA
Alarm Restore Restore 137 TR
Omit Omit/Reinstate 572 TB
Reinstate Omit/Reinstate 572 TU
12 Exit Terminator Alarm Open/Close --- --
Alarm Restore Open/Close --- --
Omit Omit/Reinstate 570 UB
Reinstate Omit/Reinstate 570 UU
13 Keyswitch Alarm Open/Close 409 OP
Alarm Restore Open/Close 409 CL
Omit Omit/Reinstate 570 UB
Reinstate Omit/Reinstate 570 UU
Non-Zone Event Types
The default Non-Zone Event codes are as follows:
No Type Event Reporting Group Contact ID SIA ID
20 Keypad Medical Alarm Priority Alarm 100 MA Keypad No *
Restore Restore 100 MH Keypad No *
21 Keypad Fire Alarm Priority Alarm 115 FA Keypad No *
Restore Restore 115 FH Keypad No *
22 Keypad Audible PA Alarm Priority Alarm 120 PA Keypad No *
Restore Restore 120 PH Keypad No *
23 Duress Code Alarm Alarm Priority Alarm 122 HA User No
Restore Restore 122 HH User No
24 Keypad Silent PA Alarm Priority Alarm 121 PA Keypad No *
Restore Restore 121 PH Keypad No *
25 Alarm Active Alarm - - - -
Restore - - - -
26 Bell Active Alarm - - - -
Restore - - - -
27 Re-arm Alarm Alarm - - Zone No
Restore - - - -
28 Verified Cross Zone Alarm Alarm Alarm 130 BV 00
Restore - - - -
29 User Code Alarm - - - User No
Restore - - - -
30 Exit Started Alarm - - - Keypad No
Restore - - - -
31 Exit Error (Arming Failed) Alarm Open/Close 457 EE 00
Restore - - - -
32 Entry Started Alarm - - - -
Restore - - - -
33 Area Arm Suite Alarm Open/Close - - Suite No 1 – 8
Restore Open/Close - - -