JBOD
The storage volume is a single HDD with no RAID support. JBOD
requires a minimum of 1 disk.
RAID 0
Provides data striping but no redundancy. Improves performance
but not data safety. RAID 0 requires a minimum of 2 disks.
RAID 1
Offers disk mirroring. Provides twice the read rate of a single disk,
but same write rate. RAID 1 requires a minimum of 2 disks.
RAID 5
Data striping and stripe error correction information provided.
RAID 5 requires a minimum of 3 disks. RAID 5 can sustain one
failed disk.
RAID 6
Two independent parity computations must be used in order to
provide protection against double disk failure. Two different
algorithms are employed to achieve this purpose. RAID 6 requires
a minimum of 4 disks. RAID 6 can sustain two failed disks.
RAID 10
RAID 10 has high reliability and high performance. RAID 10 is
implemented as a striped array whose segments are RAID 1
arrays. It has the fault tolerance of RAID 1 and the performance
of RAID 0. RAID 10 requires 4 disks. RAID 10 can sustain two
failed disks.
RAID 50
RAID 50 combines the straight block-level striping of RAID 0 with
the distributed parity of RAID 5. This is a RAID 0 array striped
across RAID 5 elements. It requires at least 6 drives.
RAID 60
RAID 60 combines the straight block-level striping of RAID 0 with
the distributed double parity of RAID 6. That is, a RAID 0 array
striped across RAID 6 elements. It requires at least 8 disks.
Edit RAID
On the RAID Information screen, press the Edit button to go to the RAID
Information screen.
Using Edit RAID, you can select RAID ID and the Spare Disk.
WARNING
If the administrator improperly removes a hard disk that should not be
removed when RAID status is degraded, all data will be lost.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thecus N7510 and is the answer not in the manual?

Thecus N7510 Specifications

General IconGeneral
RAID levels0, 1, 5, 6, 10, 50, JBOD
Hot-swap drive baysYes
Storage drive capacity- GB
Supported file systemsext3, ext4, XFS
Storage drive interfaceSerial ATA
Total installed storage capacity- TB
Number of storage drives installed-
Number of storage drives supported7
Internal memory2 GB
Internal memory typeDDR3
Processor familyIntel Atom®
Number of processors installed1
Data link protocolsTCP/IP/AppleTalk
Ethernet LAN data rates10, 100, 1000 Mbit/s
Maximum data transfer rate1000 Mbit/s
Supported network protocolsSMB/CIFS, HTTP/HTTPS, FTP, NFS v4, AFP
I/O ports1 x mic 1 x line-in 1 x audio out
Networking featuresGigabit Ethernet
Compatible operating systemsWindows 2000/XP/2003/Vista/ 7 UNIX/Linux Mac OS X
Security algorithms256-bit AES
Cables includedAC
USB 2.0 ports quantity4
Ethernet LAN (RJ-45) ports2
Bundled softwareAcronis True Image Thecus Backup Utility
Display typeLCD
Product colorBlack, Silver
Power supply unit (PSU) capacity300 W
Operating temperature (T-T)5 - 40 °C
Operating relative humidity (H-H)0 - 80 %
Sustainability certificatesRoHS
CertificationCE/FCC/C-Tick/VCCI/BSMI VMware, Citrix, WEEE
Weight and Dimensions IconWeight and Dimensions
Depth270 mm
Width210 mm
Height320 mm
Weight8400 g