113SDK (Software development Kit)
© 2010 Thorlabs
7.2.5.3
Image Pre-processing
The following functions enable and adjust the Bayer conversion (see Color Filter (Bayer Filter) ).
is_ConvertImage()
Converts a Bayer raw image into the desired output format
is_GetColorConverter()
Returns the currently set Bayer conversion mode
is_SetBayerConversion()
Sets the algorithm for Bayer conversion
is_SetColorConverter()
Sets the algorithm for Bayer conversion in the camera (not
available for Thorlabs DCx cameras)
Using Look-Up-Table (LUT) functions, you can e. g. adjust brightness or contrast after the
acquisition.
is_GetCameraLUT()
Read out current hardware LUT
is_SetCameraLUT()
Activate/deactivate hardware LUT
is_GetImageHistogram()
Computes a histogram for the image buffer passed to the
function
7.2.5.4
Get Camera Status
Using these functions, you can read out additional useful information on the camera status.
is_CameraStatus()
Returns the event counters and other information.
Enables standby mode.
is_GetAutoInfo()
Returns status information on the auto features.
is_GetCameraList()
Returns information on all connected cameras.
is_GetCameraType()
Returns the camera type.
is_GetCaptureErrorInfo
()
Displays information on errors that have occurred.
is_GetError()
Displays errors that have occurred.
is_GetUsedbandwidth()
Returns the bus bandwidth (in Mbit/s) currently used by all initialised
or selected cameras.
is_GetVsyncCount()
Returns the VSYNC counter. It will be incremented by 1 each time
the sensor starts capturing an image.
is_SetErrorReport()
Enables / disables dialogue messages for error output.
7.2.5.5
Using the Camera EEPROM
The non-volatile EEPROM of every DCx camera camera can hold user data or camera settings.
is_GetCameraInfo()
Returns the factory-set information (e.g. revision information for the
individual DCx camera components).
is_GetSensorInfo()
Returns the sensor information.
is_ReadEEPROM()
Reads out the writable data area of the EEPROM.
is_WriteEEPROM()
Writes user data to the EEPROM.
377
127
163
327
237
172
121
152
157
159
160
166
189
190
250
155
182
204
293

Table of Contents

Other manuals for THORLABS DCU22 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU22 Series and is the answer not in the manual?

THORLABS DCU22 Series Specifications

General IconGeneral
BrandTHORLABS
ModelDCU22 Series
CategorySecurity Camera
LanguageEnglish

Related product manuals