Page #304 background image
299SDK (Software development Kit)
© 2010 Thorlabs
7.4.5
isavi_ExitAVI
USB 2.0
USB 2.0
Syntax
INT isavi_ExitAVI (int nAviID)
Description
isavi_ExitAVI() terminates and deletes the instance of the DCx camera AVI interface.
Input Parameters
nAviID
Instance ID set by the isavi_InitAVI() function.
Return Values
IS_AVI_NO_ERR
Function executed successfully
IS_AVI_ERR_INVALID_ID
The indicated AVI instance could not be found. Either the
AVI ID is invalid or the instance has already been deleted
using isavi_ExitAVI() .
IS_AVI_ERR_INVALID_FILE
The AVI file could not be closed.
Related Functions
isavi_InitAVI()
isavi_OpenAVI()
isavi_CloseAVI()