Maintenance Procedures - General Quantium 310 Maintenance Manual
Page 2-4 Document Ref 941113-001 Rev 2
2.4 Access to the Hydraulic Area
The following instructions detail the procedure to be followed for the safe removal of the
hydraulic door(s).
INSTRUCTIONS
1) Locate the keys for the hydraulic door.
2) Lane oriented dispensers only: Carefully lift the relevant
nozzle(s) out of the nozzle boot(s) and place in a safe position
on the ground.
WARNING : BEWARE OF FUEL SPILLAGE.
3) Simultaneously unlock both keylocks on the hydraulic door and
carefully open the door at the top.
Note : The door is still attached by a nozzle reed switch (lane-
oriented dispensers only), retaining lanyard and earth cable.
4) Disconnect the retaining lanyard and earth cable from the inside
of the hydraulic door.
5) Lane oriented dispensers only : Locate the nozzle reed switch
on the back of the nozzle boot. Remove the clip securing the
nozzle reed switch to the nozzle reed switch bracket. Disconnect
the reed switch from the bracket.
6) Lift up the door to release from the slots in the driptray and remove
the hydraulic door completely.
7) Place the hydraulic door in a safe position.
8) Repeat for opposite side of dispenser as required.
9) To re-fit the hydraulic door(s), follow the instructions in reverse.
10) Close the dust caps to prevent water or dirt entering the keylock.
2.5 Access to the Calculator Head
The following instructions detail the procedure to be followed for the safe access to the
calculator head.
INSTRUCTIONS
1) Locate the key for the calculator head door.
2) Unlock the calculator head door on the relevant side of the
dispenser.
3) Carefully open the calculator head door.
4) Secure the calculator head door in the open position by
inserting the lever into the slot provided.
5) Repeat for the opposite side of the dispenser as required.
6) To close the calculator head door, ensure all cables remain
inside, close, lock and remove keys for safe keeping.
7) Close the dust caps to prevent water or dirt entering the key
lock.