EasyManua.ls Logo

Tokheim Quantium 310 - Changing the pulley on the PAS V3 pump

Tokheim Quantium 310
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document Ref 941113-001 Rev 2 Page 4-11
Quantium 310 Maintenance Manual Maintenance Procedures - Hydraulic
4.6 Changing the pulley on the PAS V3 pump
Before starting the maintenance procedure, please refer to section 2.
The pulley is accessed from side A of the dispenser (see section 2.3 for the identification
of the dispenser sides).
Tools required
Replacement pulley (refer to the Parts Manual for exact part identification)
Puller tool
3mm allen key
13mm spanner
Description of Parts
INSTRUCTIONS
1) Follow the instructions given in section 2.4 to gain access to the
hydraulic area.
2) Follow the instructions given in section 4.5 to remove the motor v-
belt.
3) Use a 3mm allen key to remove the grub screw on the pulley shaft
and place in a safe position.
4) If required, use the puller tool to remove the pulley (and woodruff
key) from the PAS pump. Pull from the centre part of the pulley
only - do NOT apply force with the puller fingers to the outer edges
of the pulley.
Note: Do not lose the woodruff key.
5) Fit new pulley to the PAS pump and re-fit the woodruff key.
6) Re-fit the grub screw to secure the pulley in position.
7) Re-fit the v-belt and adjust as described in section 4.5.
8) Ensure that all tools and unused materials are removed.
9) Secure the hydraulic door to the dispenser and lock.
10) Re-instate power to the dispenser.
11) Dispose of all waste accordingly.
PULLEY
GRUB
SCREW
WOODRUFF
KEY