Document Ref 941113-001 Rev 2 Page 5-13
Quantium 310 Maintenance Manual Maintenance Procedures - Electronics
5.7 Changing the CSD Board or EMT Board
Before starting the maintenance procedure, please refer to section 2.
Ensure the dispenser is isolated and all power is turned off.
The Customer Sales Display boards (CSD) are accessed from either side of the calculator
head (see section 2.3 for the identification of the dispenser sides).
Tools required
•Replacement CSD or EMT board (refer to the Parts Manual for exact part identification)
•7mm & 5.5mm nut runners
•Replacement W&M seals
•Wirecutters
•Flathead screwdriver
Description of Parts
INSTRUCTIONS
1) Follow the instructions given in section 2.5 to gain access to the calculator head on the
relevant side of the dispenser.
2) Where fitted, use wirecutters to cut the W&M seals on the
EMT security bracket.
3) Where fitted, use a 7mm nut runner to remove the four
sealing nuts and washers securing the EMT security bracket
to the display bracket.
4) Where fitted, remove the EMT security bracket completely
and place in a safe position.
5) REPLACE EMT BOARD:-
•Disconnect the tote cable from the EMT board.
•Where fitted, use wirecutters to cut the W&M seals on the
EMT board.
DOOR WITH
BRACKET
CSD
EMT