Maintenance Procedures - Hose Quantium 310 Maintenance Manual
Page 3-6 Document Ref 941113-001 Rev 2
3.3.1 RECONNECTING A SEPARATED SAFETY BREAK COUPLING
(ELAFLEX RE-USABLE TYPES ONLY)
Before starting the maintenance procedure, please refer to section 2.
Note: If the nozzle safety break coupling is irreparable then the complete
nozzle/safety break assembly must be replaced (refer to section 3.3).
Identify the relevant safety break coupling to be repaired.
Tools required
•Vice or clamping device
Description of Parts
INSTRUCTIONS
1) Follow the instructions given in section 3.3 to remove BOTH PARTS of the
separated safety break coupling.
2) Place both parts of the safety break coupling into a vice or similar clamping
device and push together until an audible “click” is heard.
3) Re-fit the safety break coupling as described in section 3.3.
4) Ensure all tools and unused materials are removed.
5) Re-instate power to the dispenser.
6) Test for any leakages.
7) Dispose of all waste accordingly.