Maintenance Procedures - Hydraulic Quantium 310 Maintenance Manual
Page 4-2 Document Ref 941113-001 Rev 2
4 MAINTENANCE PROCEDURES - HYDRAULICS
4.1 Changing the external filter on pumps with filterbox
Before starting the maintenance procedure, please refer to section 2.
The filter is accessed from side B of the dispenser (see section 2.3 for the identification of
the dispenser sides).
Tools required
Replacement filter (refer to the Parts Manual for exact part identification)
Torque wrench
Replacement O-ring
Description of Parts
INSTRUCTIONS
1) Follow the instructions given in section 2.4 to gain access to the hydraulic area.
2) Locate the filter box to be replaced.
3) Using the torque wrench, loosen and remove the four
nuts on the filter box lid.
M6 NUTS
FILTER LID
O-RING
SPRINGPLATE
FILTER
FILTERBOX

Table of Contents