EasyManua.ls Logo

Tokheim Quantium 310 - Changing the bypass valve on the EPZ pump

Tokheim Quantium 310
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Procedures - Hydraulic Quantium 310 Maintenance Manual
Page 4-8 Document Ref 941113-001 Rev 2
4.4 Changing the bypass valve on the EPZ pump
Before starting the maintenance procedure, please refer to section 2.
The bypass valve is accessed from side A of the dispenser (see section 2.3 for the
identification of the dispenser sides).
Tools required
Bypass Valve Repair Kit for EPZ Pump (refer to the Parts Manual for exact part
identification)
24mm spanner
TX30 bit
Large flathead screwdriver
Description of Parts
INSTRUCTIONS
1) Follow the instructions given in section 2.4 to gain access to
the hydraulic area.
2) Locate the bypass valve cover on the pump.
3) Using the TX30 bit, loosen and remove the four screws on the
bypass valve cover. Remove the bypass valve cover completely.
BYPASS VALVE
BYPASS
VALVE STEM
O-RING
BYPASS
VALVE
COVER
4 TORX
SCREWS
WASHER
ADJUSTER
COVER
ADJUSTER
SCREW
BYPASS VALVE
REPAIR KIT

Table of Contents

Related product manuals