Document Ref 941113-001 Rev 2 Page 4-9
Quantium 310 Maintenance Manual Maintenance Procedures - Hydraulic
4) Locate and remove the bypass valve stem from the housing.
5) Fit new bypass valve stem into the housing.
6) Re-fit the bypass valve cover.
7) Using the 24mm spanner, remove the adjuster cover.
8) Re-instate power to the dispenser.
9) Using the large flathead screwdriver, adjust the bypass valve as required. Recommended
pressure 1.2 to 2.5 bar.
Note : each turn of the bypass adjuster screw is approximately 0.1 bar.
10) Re-fit the adjuster cover.
11) Ensure that all tools and unused materials are removed.
12) Secure the hydraulic door to the dispenser and lock.