Document Ref 941113-001 Rev 2 Page 3-7
Quantium 310 Maintenance Manual Maintenance Procedures - Hose
3.4 Changing a Nozzle Reed Switch
Before starting the maintenance procedure, please refer to section 2.
Ensure the dispenser is isolated and all power is turned off.
Identify the relevant side of the dispenser with the nozzle reed switch to be replaced (see
section 2.3 for the identification of the dispenser sides). The nozzle connection is accessed
from either side A or side B of the calculator head (model dependent).
Tools required
Replacement nozzle reed switch (refer to the Parts Manual for exact part identification)
Small flathead screwdriver
24mm spanner
• 5.5mm nut runner
• Wirecutters
Description of Parts
INSTRUCTIONS
1) Follow the instructions given in sections 2.5 and 2.6 to access the
calculator head and cable glands.
2) Locate the nozzle reed switch to be changed and carefully lift the
relevant nozzle out of the nozzle boot and place in a safe position
on the ground.
WARNING : BEWARE OF FUEL SPILLAGE.
3) Remove the relevant hydraulic door as described in section 2.4.
4) Locate the nozzle reed switch on the back of the nozzle boot.
Remove the clip securing the nozzle reed switch to the nozzle reed
switch bracket.
5) Remove the nozzle reed switch from the nozzle reed switch bracket.
6) Trace the nozzle reed switch cable up the dispenser and into the
calculator head.
Note : the nozzle reed switch cable has identification tags at
each end.
NOZZLE REED
SWITCH
CLIP

Table of Contents