EasyManua.ls Logo

Tokheim Quantium 310 - Replacing the v-belt on the ECVR Unit

Tokheim Quantium 310
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Procedures - VR Quantium 310 Maintenance Manual
Page 6-2 Document Ref 941113-001 Rev 2
6 MAINTENANCE PROCEDURES - VAPOUR RECOVERY
6.1 Replacing the v-belt on the ECVR Unit
Before starting the maintenance procedure, please refer to section 2.
The V-belt is accessed side A of the dispenser (see section 2.3 for the identification of the
dispenser sides).
Tools required
Replacement v-belt (refer to the Parts Manual for exact part identification)
10mm spanner
Description of Parts
INSTRUCTIONS
1) Follow the instructions given in section 2.4 to gain access to the hydraulic area.
2) Using a 10mm spanner, loosen the four bolts on the motor. The motor will drop down into
the slots, supported by the top two bolts.
Note : support the motor during this procedure.
3) Lift up the motor to release the tension on the v-belt.
4) Whilst supporting the motor in the raised position, remove the v-
belt completely.
5) Lift up the motor into the raised position and replace the v-belt.
Note : support the motor during this procedure.
6) Using a spanner for leverage, position the motor to give the correct
tension on the v-belt.
7) Using a 10mm spanner, tighten the four bolts when the tension on
the v-belt is correct.
8) Ensure that all tools and unused materials are removed.
9) Re-fit the hydraulic door to the dispenser and lock.
10) Re-instate power to the dispenser.
11) Test the operation of the new v-belt.
12) Dispose of all waste accordingly.