Maintenance Procedures - Hydraulic Quantium 310 Maintenance Manual
Page 4-10 Document Ref 941113-001 Rev 2
4.5 Changing the V-belt on the motor
Before starting the maintenance procedure, please refer to section 2.
The motor v-belt is accessed from side A of the dispenser (see section 2.3 for the
identification of the dispenser sides).
Tools required
Replacement motor v-belt (refer to the Parts Manual for exact part identification)
13mm spanner
Description of Parts
INSTRUCTIONS
1) Follow the instructions given in section 2.4 to gain access to the hydraulic area.
2) Locate the motor v-belt. Using a 13mm spanner, loosen the two locking nuts on the motor
bracket.
3) Using a 13mm spanner, loosen and remove the two motor V-belt
tension screws.
4) Remove the motor v-belt completely.
5) Fit new motor v-belt.
6) Using the 13mm spanner, re-fit and tighten the motor v-belt tension
screws until the correct tension is achieved.
7) Using the 13mm spanner, tighten the locking nuts against the pump
support bracket.
8) Ensure that all tools and unused materials are removed.
9) Re-fit the hydraulic panel to the dispenser and lock.
10) Re-instate power to the dispenser.
11) Test operation of the new v-belt.
12) Dispose of all waste accordingly.
V-BELT
MOTOR
PULLEY
V-BELT
TENSION
SCREWS
PUMP SUPPORT
BRACKET

Table of Contents